EH330, EH430 E and ECC Condensing Unit
Remote Low Side Cuber User Manual

Configuration

A remote low side cuber system includes two
sub systems: an ice head section and a remote
condensing unit. Additionally, there are several
models of each sub-system and this manual covers
all of them.
The ice making sections are designed for use indoors
in a controlled environment. The remote condensing
units are designed to operate outdoors. Each sub-
system has limits for power, water and temperature.
Operational Limitations:
Air Temp (IH)
Air Temp (CU)
Water Temp
Water Pressure
Water Conductivity
Voltage (IH)
Voltage (CU)
IH = Ice Head, CU= Condensing Unit
Do Not operate the machine in conditions beyond
these limitations. Doing so will void the warranty.
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance. They meet or exceed the standards of
UL and NSF.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specifically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specifications and
design are subject to change without notice.
System Information
Prodigy Eclipse
Condensing Unit (CU)
System Size
Model
1200
ECC1200-32A
1400
ECC1410-32A
1400
ECC1410-3A
1800
ECC1800-3A
Minimum
Maximum
50
F
100
o
o
-20
F.
120
o
o
40
F.
100
o
o
20 psi
80 psi
10
microSiemens/cm
104
126
198
253
Electrical
(volts/Hz/phase)
208-230/60/1
208-230/60/1
208-230/60/3
208-230/60/3
Warranty
Refer to the warranty coverage in effect when the
equipment was sold. Warranty statements are
included with each product.
Systems:
Each sub-system is a separate entity that carries
its own model and serial number. They must be
combined to create a remote cuber low side system.
Notes: Voltage Codes are at the end of the model
number. Codes read Voltage/Hertz/Phase. Those
F.
related to these products include:
F.
-1 = 115/60/1
F.
-3 = 208-230/60/3
-32 = 208-230/60/1
Tubing kits are required to interconnect the head to
the CU
20 foot: 3BRTE20-EH,
35 foot: 3BRTE35-EH
50 foot: 3BRTE50-EH
75 foot: 3BRTE75-EH
Interconnecting 24 volt control wire ships in the
condensing unit.
Warning:
Ice Making Head (IH)
Model
EH330SL-1D or EH330ML-1E
EH430SL-1D or EH430ML-1E
EH430SL-1D or EH430ML-1E
EH430SL-1D or EH430ML-1E
June 2018
Page 2
Electrical
(volts/Hz/phase)
115/60/1
115/60/1
115/60/1
115/60/1