Configuration - Scotsman EH222 Quick Start Manual

Prodigy eclipse cuber with ecc condensing unit
Table of Contents

Advertisement

EH222 and Condensing Unit
Remote Low Side Cuber Service Manual

Configuration

A remote low side cuber system includes two sub
systems: an ice making head and a remote air cooled
condensing unit. This manual covers the EH222 head
and the condensing units that go with it.
The ice making heads are designed for use indoors
in a controlled environment. The remote condensing
units are designed to operate outdoors. Each sub-
system has limits for power, water and temperature.
Operational Limitations:
Minimum
Air Temp (at head) 50
Air Temp (CU)
-20
Water Temp
40
Water Pressure
20 psi
Water Conductivity 10
Voltage (at head)
104
Voltage (CU)
198
CU= Condensing Unit
Do Not operate the machine in conditions beyond
these limitations. Doing so will void the warranty.
System Size Condensing Unit (CU)
Model
800
ECC0800-32A
800
ECC0800-3A
1000
ECC1410-32A
1000
ECC1410-3A
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance. They meet or exceed common agency
standards.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specifically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specifications and
design are subject to change without notice.
Maximum
F
100
o
o
F.
120
o
o
F.
100
o
o
80 psi
any
microSiemens/cm
126
253
Electrical (volts/Hz/phase
208-230/60/1
208-230/60/3
208-230/60/1
208-230/60/3
Warranty
Refer to the warranty coverage in effect when the
equipment was sold. Warranty statements are
included with each product.
Systems:
Ice making heads and condensing units have their
own model and serial numbers. They must be
combined to create a remote cuber low side system.
Notes: Voltage Codes are at the end of the model
number. Codes read Voltage/Hertz/Phase. Those
F.
related to these products include:
F.
-1 = 115/60/1
F.
-3 = 208-230/60/3
-32 = 208-230/60/1
System Information
Tubing kits are required to connect the head to the
condensing unit.
Interconnecting 24 volt control wire ships with the
condensing unit.
Ice Making Head
Model
EH222SL-1C
same
same
same
August 2013
Page 3
Electrical (volts/Hz/phase)
115/60/1
same
same
same