Technology
TECHNICAL
Transmitter frequency
SPECIFICATION
Transmitter radiated power
Transmitter power density
Mounting height
• FALCON DR
• FALCON XL-DR
Tilt angles
Detection zone
• FALCON DR
(mounting height of 5m)
• FALCON XL-DR
(mounting height of 2.5m)
Detection mode
Minimum speed
Supply voltage
Mains frequency
Power consumption
Two Output relay (free of potential change-over contact)
• Max. contact voltage
• Max. contact current
• Max. switching power
DESCRIPTION OF
THE SENSOR
INSTALLATION
TIPS
The sensor must be firmly
fastened to prevent from
vibrating.
75.5268.01 20070111
FALCON DR: double relay / high mount • FALCON XL-DR: double relay / low mount
: Microwave and
microprocessor
: 24.125 GHz
: <20 dBm EIRP
: < 5 mW/cm²
: from 11.5' (3.5m) to 23' (7m)
: from 6.5' (2m) to 11.5' (3.5m)
: 0° to 180° in elevation
: 13' (W) x 16' (D)
4m (W) x 5m (D)
: 13' (W) x 6.5' (D)
4m (W) x 2m (D)
: Motion
: 2 in (5cm)/s (measured in the
sensor axis)
: 12V to 24V AC ±10%
12V to 24V DC +30% / -10%
: 50 to 60 Hz
: < 2W (VA)
: 42V AC
: 1A (resistive)
: 30W (DC) / 60VA (AC)
The sensor must not be placed
directly behind a panel or any kind
of material.
FALCON DR / FALCON XL-DR
MOTION SENSORS FOR INDUSTRIAL DOORS
Hold time
Temperature range
Degree of protection
Norm conformity
Dimensions
Weight
Material of housing
Material of bracket
Length of cable
Manual adjustment
• Orientation of sensing field (mechanically)
• Multiple functions (by push buttons)
Remote control adjustments
• Sensitivity
• Hold time
• Detection mode
• Pedestrian and parallel traffic rejection mode
• Output configuration
• Security
The sensor must not have
any object likely to move or
vibrate in its sensing field.
USER'S GUIDE
: 0.5s to 9s (adjustable)
: -22°F to +122°F (-30°C to +60°C)
: IP65
: R&TTE 1999/5/EC
EMC 89/336/EEC
: 4" (W) x 5" (D) x 3 ¾" (H)
102 mm (W) x 127 mm (D) x 96 mm (H)
: 0.88 lbs (0.4 kg)
: ABS and polycarbonate
: Anodized aluminium
: 33' (10m)
Tranceiver module
(planar antenna)
Green LED
Infrared Receiver
Red LED
2 Push Buttons
Microprocessor
Terminal block
The sensor must not have any
fluorescent lighting in its
sensing field.
Page 1 of 7