Mitsubishi FR-S520-0.1K to 3.7K(-R)(-C) Instruction Manual page 23

Fr-s500 series
Table of Contents

Advertisement

4.2.2 Example: Changing the Pr. 30 setting from "0" to "1"
(The extended parameters are made valid by setting "1" in Pr. 30 "extended
function display selection". Refer to page 27 for the extended function parameter
list and to the instruction manual (detailed) for details.)
Operation
1.
Confirm the RUN indication and operation
mode indication.
The inverter must be at a stop.
The inverter must be in the PU operation
mode. (Press the
2.
Press the
MODE
parameter setting mode.
3.
Turn the setting dial
(Pr. 30) appears.
4.
Press the
SET
currently set value.
"
"
(factory setting) appears.
5.
Turn the setting dial
it to the set value of
6.
Press the
SET
By turning the setting dial
Press the
Press the
After parameter setting is complete, press the
history or twice to return to the monitor display. To change the setting of another
parameter, perform the operation in above steps 3 to 6.
Error display?
• If the operation panel does not have the write precedence (only for
the type with RS-485 communication function)
• If write was performed during operation
• If write was performed in the external operation mode
Remarks
If the setting has not been changed, the value does not flicker and the next
parameter number appears.
PU
key.)
EXT
key to choose the
until
key to read the
to change
" "
.
key to set the value.
key to show the setting again.
SET
key twice to show the next parameter.
SET
MODE
SET
SET
Flicker ... Parameter setting complete!!
, you can read another parameter.
MODE
key once to show the alarm
18
Display
RUN
PU
EXT
The parameter
number read
previously
appears.