Graco e-Xtreme Operation, Repair, And Parts page 33

Table of Contents

Advertisement

Ex45
Ex45 e e e - - - Xtreme
Ex45
Xtreme Sprayers
Xtreme
Sprayers
Sprayers
Maximum fluid working pressure
Stroke length
Maximum continuous cycle rate
Tip Size
Weight
Wetted parts
Maximum fluid temperature
Operating temperature range
Input voltage
Input power
Minimum Recommended generator size
Oil capacity
Oil specification
Inlet / Outlet Sizes
Fluid inlet size
Fluid outlet size
Hose Requirements
Minimum pressure
Minimum length
Minimum ID
Maximum resistance per ISO 8028
Sound Emissions (per ISO 9614) for Normal Operation (Spraying @ 20 cpm)
Sound Pressure LpA Average
Sound Power LwA Total Power
Sound Emissions (per ISO 9614) for Maximum Speed (Flushing @ 44 cpm)
Sound Pressure LpA Average
Sound Power LwA Total Power
3A3164D
U.S.
U.S.
U.S.
4500 psi
4.75 in.
44 cycles per minute
295 lb
Carbon Steel, Alloy Steel, 304, 440 and 17–PH Grades
of Stainless Steel, Zinc and Nickel Plating, Ductile Iron,
Tungsten Carbide, PTFE; Leather, Aluminum
See Models information in Operation/Repair manual.
23° to 120° F
200–240 VAC, single phase, 50/60 Hz
1.0–1.2 quarts
Graco part number 16W645 silicone-free ISO
220 synthetic EP gear oil
1 in. npt(m) [also includes 1 in. nps(swivel) to
1 in. npt(m) adapter elbow]
1/2 npt(m) [also includes 1/2 npt(f) to 3/8 npt(m) adapter]
The minimum hose pressure rating should be equal to or
greater than the maximum fluid working pressure of sprayer
50 ft.
3/8 in.
9,100 ohms/ft
Technical Specifications
Metric
Metric
Metric
310 bar, 31.0 MPa
120 mm
.021 in.
135 kg
-5° to 50° C
2.5 kVA
5 kW
0.9–1.1 liters
15 m
10mm
30,000 ohms/m
70.2 dBA
76.7 dBA
77.4 dBA
85.1 dBA
33