Pressure Relief Procedure; Trigger Lock - Graco e-Xtreme Operation, Repair, And Parts

Table of Contents

Advertisement

Setup
Pressure Relief
Relief Procedure
Procedure
Pressure
Pressure
Relief
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
1. Engage gun trigger lock.
2. Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob
in to lock.
3.
Turn power switch (E) OFF.
12
4.
Disengage gun trigger lock.
5.
Hold gun firmly against a grounded metal pail.
Trigger the gun.
6. Engage gun trigger lock.
7. Drain
Drain
Drain fluid:
fluid: Place the drain tube in a grounded
fluid:
waste pail. Slowly open fluid drain/purge valve
(C), and drain fluid into a waste pail.
8. If you suspect the spray tip or hose is completely
clogged or that pressure has not been fully
relieved:
a. VERY SLOWLY loosen the tip guard
retaining nut or hose end coupling to relieve
pressure gradually.
b. Loosen the nut or hose end coupling
completely.
c. With tip removed, trigger the gun into the
bucket.
Trigger

Trigger Lock

Trigger
Lock
Lock
Always engage the trigger lock when you stop
spraying to prevent the gun from being triggered
accidentally by hand or if dropped or bumped.