Description
2.4 How do you determine the replacement encoder?
Requirement
You require the motor Article number.
Procedure
1. Take the Article number of the motor from the motor rating plate.
2. Compare the Article number with the following tables:
– For the 1FG1, at the 9th position, e.g. 1FG1□□□-□Q□□□-□□□□ there is a singleturn
– For 1FK7 and 1FT7 at the 14th position, e.g. 1FK7□□□-□□□□□-□B□□ there is a
26
20 bit absolute encoder
singleturn 24 bit absolute encoder
Encoder loaded with data and integrated DRIVE-CLiQ interface (DQI), RJ45 plug connector
Encoder type, replaceable
Absolute encoder, single-
turn 24 bit
Motor Article number:
1FK7□□□-□□□□□-□B□□
Absolute encoder 24 bit +
12 bit multiturn
Motor Article number:
1F□7□□□-□□□□□-□C□□
Absolute encoder, single-
turn 20 bit
Motor Article number:
1FK7□□□-□□□□□-□Q□□
1FG1□□□-□Q□□□-□□□□
Absolute encoder 20 bit +
12 bit multiturn
Motor Article number:
1FK7□□□-□□□□□-□R□□
1FG1□□□-□R□□□-□□□□
For motor
1FK703
1FK704
1FK706
1FK708
1FK710
1FK703
1FK704
1FK706
1FK708
1FK710
1FK703/1FG1□□□-□□C
1FK704/1FG1□□□-□□D
1FK706/1FG1□□□-□□E
1FK708/1FG1□□□-□□F
1FK710/1FG1□□□-□□G
1FK703/1FG1□□□-□□C
1FK704/1FG1□□□-□□D
1FK706/1FG1□□□-□□E
1FK708/1FG1□□□-□□F
1FK710/1FG1□□□-□□G
Replacing an encoder for SIMOTICS S-1FK7 G2, S-1FG1 and S-1FT7
Designation
Article number
AS24DQI-72
6FX2001-5JD24-2QC1
AS24DQI-88
6FX2001-5JD24-2DC1
AM24DQI-72
6FX2001-5JE24-2QC1
AM24DQI-88
6FX2001-5JE24-2DC1
AS20DQI-72
6FX2001-5JD20-2QC1
AS20DQI-88
6FX2001-5JD20-2DC1
AM20DQI-72
6FX2001-5JE20-2QC1
AM20DQI-88
6FX2001-5JE20-2DC1
Service Manual, 01/2018, A5E34676237B AC