SNMP Configuration
The SNMP Configuration menu displays a list of the parameters that allow you to
set and change values, parameters, and addresses within an SNMP management
environment. To change any setting, type in the corresponding number. The screen
is refreshed, and the command line displays the current parameter value for the
selected parameter and allows you to enter new data. The SNMP configuration
parameters that can be changed are listed on the screen as follows:
1---SNMP Read Community String
2---SNMP Read/Write Community String
Warning: With the cursor at selections 1 or 2, pressing Enter without typing a
selection deletes the current setting.
3---Trap Receiver 1 Community Name and IP Address
4---Trap Receiver 2 Community Name and IP Address
5---Trap Receiver 3 Community Name and IP Address
6---Trap Receiver 4 Community Name and IP Address
7---Authentication Trap Generation
8---LinkUp/LinkDown Trap Generation
3-16
Sets the in-band read-only SNMP operations. Default setting is public.
Sets the in-band read/write SNMP operations. Default setting is private.
Number one of four allowed Trap IP Addresses. Successive Trap Address
fields are numbered #2, #3, and #4. Each of the Trap addresses has an
associated Community String. Default value is 0.0.0.0. (no IP address
assigned) and public.
Enables or disables sending a trap on an SNMP authentication failure. Default
setting is Disabled.