Power State At Cold Start; Power State At Cold Start Get; Power State At Cold Start Report - Planar VM55LX-X User Manual

Vm series displays
Hide thumbs Also See for VM55LX-X:
Table of Contents

Advertisement

10. Power State at Cold Start

Use this command is to set, update, and store the cold start power state.

10.1 Power State at Cold Start Get

Bytes
0xA4 = Power State at Cold
DATA[0]
Start - Get
Example: (Display Address 01)
Header
Monitor ID
0xA6
0x01

10.2 Power State at Cold Start Report

Bytes
0xA4 = Power State at Cold
DATA[0]
Start- Report
DATA[1]
Power State at Cold Start
Example: Report status of Forced On for Power State at Cold Start (Display Address 01)
Header
Monitor ID
0x21
0x01
VM Series Displays RS232 User Guide
020-1359-00A
Bytes Description
Category
Code0
Code1
0x00
0x00
0x00
Bytes Description
Category
Page
Length
0x00
0x00
0x04
Bits
Description
Get Power State at Cold Start
State
Length
Data Control
0x03
0x01
Bits
Description
Report from Power state at Cold
Start state
0x00 = Power Off
0x01 = Forced On
0x02 = Last Status
Data Control
Data[0]
0x01
0xA4
General
Data[0]
Checksum
0xA4
0x01
Data[1]
Checksum
0x01
0x80
Page | 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vm55mx-xVm55lx-u

Table of Contents