X12TE-GRID using X12PU-BGK to pull-up to grid

Using a X12TE-GRID combined with the X12PU-BGK can be pulled up to the grid.
To pull-up to the X12TE-GRID, do the following:
1.
2.
3.
4.
5.
6.
7.
8.
Electro-Voice
Attach the two (2) pull-up link bars to the sidearms.
Insert the attached quick-release pins.
Verify all quick-release pins are inserted completely through the sidearm and securely locked
in position.
Attach the X12PU-BGK bottom section to the bottom element.
Attach a 5/8-inch shackle (A) to the pick point on the spreader bar.
Ensure the shackle is rated for overhead lifting.
Attach one (1) end (B) of the 3-foot wire rope sling to the shackle.
Attach the opposite end (C) of the 3-foot wire rope to the pull-up hoist.
Attach a chain bag to the pull-up hoist and insert the unextended chain into the chain
bag.
Verify all hooks, pins, shackles, and other associated rigging components are properly
positioned and secure before lifting the array.