Download Print this page

Samsung Color Dual Quad Network Observation System SSC21WEB User Manual page 29

Color dual quad network observation system
Hide thumbs Also See for Color Dual Quad Network Observation System SSC21WEB:

Advertisement

SSC21WEB-1
2004.8.25
5:38 PM
Page 29
Allows users to set the ALARM MODE for each camera.
Move to #6. ALARM MENU by using œ œ
MENU, and press the ENTER SWITCH to display the OSD as shown in the figure below. (The
figure shows the initial setting status.)
06/01/03
ALARM
SETTING
CAM1
CAM2
CAM3
CAM4
CAM5
CAM6
CAM7
CAM8
HOLD TIME
ALARM ON TIME
ALARM OFF TIME
BUZZER
(1) CAM1 to CAM8 item sets whether the alarm sensor connected to the camera is used or not.
(ON: Alarm function setting, OFF: Alarm function canceling)
(2) HOLD TIME item sets time to freeze alarm operation when alarm occuring.
(HOLD TIME to be set: 05SEC ~ 1MIN ~ 30MIN)
(3) ALARM ON/OFF TIME item sets beginning time (ON) and end time (OFF) that monitor
recognizes alarm operation as alarm event.
* Note :Even if CAMERA ALARM is set to ON, alarm operation is not carried at time band except
pre-set ALARM ON/OFF TIME.
(4) BUZZER item sets whether or not buzzer device set in monitor is used at an ALARM or LOSS
occurring.
(ON: Buzzer operation, OFF: NA)
13:14:00
ON
ON
ON
ON
ON
ON
ON
ON
05SEC
00:00
00:00
ON
Eng-29
√ √ SWITCH at SETUP

Advertisement