Cleaning, Maintenance And Storage - Stanley SIG 1900S Original Instructions Manual

Inverter generator
Hide thumbs Also See for SIG 1900S:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Important!
The 12 V DC output of the generator is not treated by a
precise electric circuit.
Never use it to power any precise DC instrument.
Important!
When using the generator to powering a heating device.
Please do keep the powered heating device far from the
generator.
7.4 Switching off the engine
- Turn off any electric devices.
- Before you switch off the generator, allow it to run
briefly with no consumers so that it can "cool down".
- Turn the ECS switch to "OFF"
- Disconnect any electric devices
- Move the Engine switch (11) to position "STOP".
- Turn the fuel cock knob to"OFF"
- Turn the fuel tank cap air vent knob to "OFF"after the
engine has completely cooled down
7.5 Overload cut-out for socket-outlets
Important!
The generator is fitted with an overload cutout. This
shuts down the sockets (4). You can restart the sockets
by restart the generator.
Important!
If this happens, reduce the electric power you are taking
from the generator or remove any defective connected
appliances.
Important!
Defective overload cut-outs must be replaced only by
overload cut-outs of identical design and with the same
performance data. If repairs are necessary, please
contact your customer service center.

8. Cleaning, maintenance and storage

Switch off the generator and pull the spark plug boot
from the spark plug before doing any cleaning and
maintenance work on the equipment.
8.1 Cleaning
- Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible. Wipe the
equipment with a clean cloth or blow it with compressed
air at low pressure.
- We recommend that you clean the device after each
time finished using.
- Clean the equipment regularly with a moist cloth and
some soft soap. Do not use cleaning agents or solvents;
these could attack the plastic parts of the equipment.
Ensure that no water can seep into the device.
8.2 Air filter (B16)
In this connection, please also read the service
information.
- Clean the air filter at regular intervals, and replace it if
necessary.
- Remove fixing bolt on the air filter cover.
- Remove the filter elements (B16).
Important!
Do not use abrasive cleaning agents or petrol to clean
the elements.
- Clean the elements by tapping them on a flat surface.
In cases of stubborn dirt first clean with soapy water,
and then rinse with clear water and air dry.
- Assemble in reverse order.
8.3. Spark plug (B4-8)
Check the spark plug (item 17) for dirt and grime after 50
hours of operation and if necessary clean with a copper
G
B