7.6

Diagnostic functions

7.6.1

Diagnostics of the communication module via LED display

LED
BUS
PORT 1 /
PORT 2
PROFINET Communication Module for SIRIUS Soft Starter 3RW44
Manual, 12/2013, A5E31996495002A/RS-AA/001
LED display
Description
Green
Device performing data
exchange
Yellow
Device is not initialized and
bus error
Yellow blinking
Communication module is
inserted but not activated
Yellow flickering
Firmware update is
running/not yet complete
Yellow/green
Device is not initialized and
blinking
parameter assignment error
Red
Bus error
Red blinking
Parameter assignment error,
configuration error
Red flickering
Basic factory settings are
being restored
Off
Bus is not connected or
bus error
CPU is in Stop
Green
Physical Ethernet
connection is present
Green blinking
Blink test has been activated
(e.g., via STEP 7)
Off
There is no Ethernet
connection between the
PROFINET interface of your
PROFINET device and a
communication partner (e.g.,
IO controller)
Functions
7.6 Diagnostic functions
Measures in cases of error /
error causes
Send in the basic unit
For activation of the
communication module, see
section Commissioning
(Page 31)
Restart after aborted FW update
Send in the basic unit
Check the fieldbus interface
Incorrect or invalid parameters
received
Connect the bus or check the
bus parameters
Check the installation of the
communication module
Set CPU to RUN
Establish an Ethernet
connection
The 3RW44 you are using is
not PROFINET-capable
59