Installation - Siemens 6RA7086-6KS22 Operating Instructions Manual

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

01.04
5

Installation

CAUTION
Failure to lift the converter in the correct manner can result in bodily injury and/or property
damage.
The device must always be lifted by properly trained personnel using the appropriate
equipment (i.e. protective gloves, etc.).
To preclude the risk of deformation damage to the housings of converters with rated DC
current of 720A or higher, the lifting lugs used to raise them must not be subjected to any
horizontal forces.
The user is responsible for installing the converter, motor, transformer as well as other
equipment according to safety regulations (e.g. DIN, VDE), as well as all other relevant
national or local regulations regarding cable dimensioning and protection, grounding, isolating
switch, overcurrent protection, etc.
The converter must be installed in accordance with the relevant safety regulations (e.g. DIN,
VDE), as well as all other relevant national and local regulations. It must be ensured that the
grounding, cable dimensioning and appropriate short-circuit protection have been implemented
to guarantee operational safety and reliability.
Installation of SIMOREG devices in cabinets in accordance with UL 508 C standards
When the drive is provided in a panel (enclosure), the panel is ventilated and designated "Type 1".
The minimum size panel (enclosure) to be used with the drive is 600 mm length, 600 mm width,
2200 mm height.
Possible lifting method for converters with rated DC current of 1500A to 3000A
Siemens AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Installation
5-1