Parameterization of SIMOREG converters for parallel connection

6.3.2.1

Standard operating mode

Master
U800 = 1
U800 = 2
U803 = 0
U804.01 = 30 control word 1
U804.02 = 31 control word 2
U804.03 = 167 Actual speed value
U805 = 1
0
U806 = 12
13
14
15
16
Set U806.02 like U806.01
P082 <> 0
Set P083 depending on the source of the
actual speed value
Rated
P100 =
Number
Set P648, P649 depending on the source
P110 = Actual armature resistance
x no. of SIMOREG converters
P111 = Actual armature inductance
x no. of SIMOREG converters
The optimization run for current controller
and precontrol (P051 = 25) sets these
parameters correctly.
For further details about the operating principle of parallel connections between SIMOREG
converters, please refer to Section 8, Function Diagrams, Sheet G195 (paralleling interface).
Notes:
• Control commands "Switch-on/Shutdown", "Enable operation", "Emergency stop" etc. must be
connected to a group of parallel-connected SIMOREG converters via the master device.
Terminals 37 and 38 must be permanently connected to terminal 34 on the slave !
• Optimization runs must be started on the master device. All slaves must be connected and
ready to run when optimization is started.
6-22
Paralleling interface active
if a SIMOREG CCP is
used
"N+1 mode" not active
(bus termination)
(no bus termination) on all other units
master for one slave
master for 2 slaves
master for 3 slaves
master for 4 slaves
master for 5 slaves
operating mode for field
motor
current
of
SIMOREG
units
of the control word
Slaves
U800 = 2
U804.01 = 32 status word 1
on the two end units
(at both physical ends of the bus cable)
U806 = 2
U806 = 2 and 3
U806 = 2, 3 and 4
U806 = 2,3,4 and 5
U806 = 2,3,4,5 and 6
Set U806.02 like U806.01
P082 = 0
P083 = 4
P609 = 6023
Rated
P100 =
Number
P648 = 6021
P649 = 6022
P821.01 = 31 Suppress alarm A031
P110 = set as on master
P111 = set as on master
Paralleling interface active
Use master firing pulses
1 slave
2 slaves
3 slaves
4 slaves
5 slaves
internal field is not used
Freely connected actual speed value
Use actual speed value of master
motor
current
of
SIMOREG
units
Use control word 1 from master
Use control word 2 from master
Siemens AG
SIMOREG DC Master
Operating Instructions
05.05
6RX1700-0AD76