Mitsubishi Electric MELSEC iQ-R Series Safety Manual page 38

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Programs to be used in a program for realizing safety functions
Configure input and output data of a program for realizing safety functions using safety data. Determine the safety/non-safety
of input/output data as follows.
■Devices transferring safety data through safety communications with safety remote I/O
module
The safety data of devices transferring safety data to be refreshed by safety communications with the safety remote I/O
module is a safety data.
Safety CPU
Station
SA\X1F - SA\X0
No.1
SA\X3F - SA\X20
SA\X5F - SA\X40
SA\X7F - SA\X60
SA\Y1F -
SA\Y7 -
Station
SA\Y8
SA\Y0
No.1
SA\Y3F - SA\Y20
SA\Y5F - SA\Y40
SA\Y7F - SA\Y60
*1 These are inputs such as an emergency stop switch, safety switch, and light curtain.
*2 These are the outputs such as a power source of robots.
User devices to be refreshed by communications with standard remote I/O module can be used only by standard program.
When using standard remote I/O module inputs and outputs with safety program, use standard/safety shared label to deliver
data between standard and safety programs. ( Page 37 Standard/safety shared label)
■Devices transferring safety data by safety communications between Safety CPUs
The safety data of devices transferring safety data to be refreshed by safety communications between Safety CPUs with the
CC-Link IE Field Network is a safety data. For details, refer to the following.
 MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
4 PRECAUTIONS FOR USE OF SAFETY PROGRAMMABLE CONTROLLER
36
4.2 Precautions for Programming
CC-Link IE Field Network
master/local module
Safety remote I/O module (station No.1)
Main module
Extension module
NZ2GFSS2-32D
NZ2EXSS2-8TE
X1F-X0
Input*
on/off
Output*
Y7-Y0
on/off
1
2

Advertisement