■Wiring diagram and parameter settings
<CCIEF remote (1): SR_IO1>
Wire the enabling switch, electromagnetic contactor, and safety switch to safety remote I/O module as follows. For details on
the terminal block, refer to the following.
 CC-Link IE Field Network Remote I/O Module (With Safety Functions) User's Manual
Safety switch
*1
2NC
[5] [6]
[1]
[3]
[2]
[4]
Above [1] to [6] are connected to the one with same numbers.
*1 Wire a safety switch having two normally closed contacts with direct opening action to input terminal and test pulse terminal, using a
guard switch with an interlock.
*2 Use two electromagnetic contactors operatable by 24VDC and 0.5A.
*3 Connect normally closed contact of the electromagnetic contactor between the input terminal and test pulse terminal.
*4 Connect the two normally open contacts of the three-position enabling switch to the input terminal and test pulse terminal.
5 SAFETY APPLICATION CONFIGURATION EXAMPLES
122
5.1 System Configured by a Safety CPU
24VDC
24VDC
Guard unlock
Three-position
enabling switch
Open
Guard
Electromagnetic
*2*3
contactor
L3
24VDC
L2
L1
Electromagnetic
*2*3
contactor
CCIEF remote (1)
NZ2GFSS2-32D
Network No.1
Station No.1
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
19
IO24V
20
IO24G
1
X0
2
X1
[1]
3
X2
[2]
4
X3
9
X8
10
X9
*4
[3]
23
T0
[4]
24
T1
25
T0
26
T1
27
T0
28
T1
CCIEF remote (1)
NZ2EXSS2-8TE
Network No.1
Station No.1
19
IO24V
20
IO24G
1
Y0
2
COM-
3
Y1
4
COM-
5
Y2
[5]
6
COM-
[6]
Terminal block for power supply and FG (input)
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
Spring clamp terminal block (input)
Spring clamp terminal block (output)