Mitsubishi Electric MELSEC iQ-R Series Safety Manual page 167

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

• Network configuration settings
Set the number of link device points and assignment of slave stations to the master station. If selecting "Local Station" in
"Required Settings", setting is not possible.
Operating procedure
1.
Select a module from "Module List", and drag and drop it to the list of stations or the network map.
2.
Select and input parameters as shown below.
3.
Select "Close with Reflecting the Setting" and complete "Network Configuration Settings". If the window is closed using
the [] button, the settings are not reflected.
Window
List of stations
Network map
Displayed items
Item
Description
Assignment Method
Number of points or Start number
Total number of slave
2
stations
Item
Range/value
CCIEF programmable controller
Master (1-0)
Model
RJ71GF11-T2
STA#
0
Station Type
Master Station
RX/RY
Points: (Unavailable)
Start: (Unavailable)
End: (Unavailable)
RWr/RWw
Points: (Unavailable)
Start: (Unavailable)
End: (Unavailable)
Reserved/Error Invalid
No Setting
Station
Network synchronous
Asynchronous
communication
Drag and drop a module.
CCIEF programmable controller
Local (1-1)
RJ71GF11-T2
1
Local station
Points: 32
Start: 0060
End: 007F
Points: 16
Start: 0030
End: 003F
No Setting
Asynchronous
5 SAFETY APPLICATION CONFIGURATION EXAMPLES
5.2 System to Which Multiple Safety CPUs are Connected
CCIEF programmable controller
Local (1-2)
RJ71GF11-T2
2
Local station
Points: 32
Start: 0080
End: 009F
Points: 16
Start: 0040
End: 004F
No Setting
Asynchronous
5
165