BE FORE Y O U BE GI N
GUY WIRE CHECK
Checking a fan's guy wires for tension and inspecting for frayed sections could prevent a problem before it occurs. Fan
owners should confirm that the guy wires are not wrapped around any sharp edges. We recommend attaching guy wires
to the building with provided clamps to prevent fraying. Turnbuckles should be checked to ensure tightness. If they are
loose, the guy wire cables need to be re-tensioned.
AIRFOIL CLEANING
Depending on the commercial application of the fan, there can be quite a bit of dust or other particulates that cling
to the fan's airfoils. We recommend fan owners keep airfoils clean by having a maintenance person or skilled trade
professional–who has experience using a lift–wipe the fan airfoils with a rag or sponge using hot water or regular cleaning
solutions. Please do not use chlorine or any chemicals containing chlorine.
RETENTION SYSTEM CHECK
Each fan is installed with a retention system. The retention cable is attached to the motor and wraps around the building
structure. The safety cable is an important part of the safety system and protects users from a catastrophic event. It is
critical for fan owners to ensure that it is intact and properly secured.
REPLACEMENT PARTS
Please call our Technical Department at 1-844-593-FANS (3267).
5
MAINTENANCE