D. Venting Systems
Chimney Connector:
It is also known as flue pipe or stove pipe. It must be
152mm minimum diameter stainless steel connector pipe.
Chimney:
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements as specified below.
WARNING
Risk of Fire!
Follow venting manufacturer's clearances and
instructions when installing venting system.
E. Inspections
Existing chimneys should be inspected and cleaned by a
qualified professional prior to installation. The chimney must
not have cracks, loose mortar or other signs of deterioration
and blockage. Hearth & Home recommends a certified pro-
fessional or a technician, under the direction of a certified
professional.
WARNING
Fire Risk.
Inspection of Chimney:
Chimney must be in good condition.
Factory-built chimney must be 152mm.
F. Larger Chimneys
Hearth & Home recommended that chimneys with larger
diameters than 152mm be fully relined. An oversized flue
can affect draft and impair performance and will allow
increased build-up of creosote.
NOTICE: Check with your local building authorities.
17 August, 2018
7075-177A
VOYAGEUR GRAND AU
13