Observing LED Behavior
Table A-1
LED Behavior
The Link LED is not lit
when connected to a
10BaseT Ethernet hub.
Network LED is solidly lit.
Network LED is not lit.
An undefined difficulty
occurred at startup, but the
cause cannot be
determined from LED
behavior.
A-4
Hardware Problems and Solutions (Continued)
Possible Cause
There is no link integrity.
Heavy traffic can cause the
network LED to blink so
rapidly that it appears to be
solidly lit.
However, if packets cannot
be passed, you might have
an incorrectly cabled
network.
If the PortMaster is not
receiving, or sending
traffic, the network LED is
not lit.
If packets cannot be
passed, the network might
be cabled incorrectly.
Refer to the solution
column.
Solution
Verify that DIP switches 4 and 5 are
up and that you have a working
10BaseT cable properly connected to
the PortMaster and to the hub. Turn
the power off and on to activate the
DIP switch setting.
Verify that the network cabling is
correct.
Verify that the network cabling is
correct.
Verify that the network cabling is
correct.
Try booting in console mode, and
observe the boot messages. See
"Observing Boot Messages" on page
A-5. If the boot messages do not
suggest a solution, record the
information and contact Lucent
Remote Access Technical Support.
Communications Server Hardware Installation Guide