Power-on or Reset
Y
Can bus power
fails
RUN LED
ERR LED
7-Segment display
Right dot inicator
Left dot indicator
CJ-series User Defined CAN Unit Operation Manual for NJ-series CPU Unit (W517)
Start
ST1
Initialise hardware
and software
Wrong CPU unit?
N
ST3
Not
Configured
Configure
memory area
N
ST4
Unit configured
Enable CAN
communication
Y
ST5
Communicating
CAN bus off
Disable CAN
communication
RUN LED
= GREEN
ERR LED
= OFF
7-Segment display
= 02
Right dot inicator
= OFF
Left dot indicator
= ON
= GREEN
= OFF
= 01
= OFF
= ON
6 Troubleshooting and Maintenance
ST2
Y
Fatal Error
Y
N
N
Y
RUN LED
= OFF
ERR LED
= OFF
7-Segment display
= OFF
Right dot inicator
= OFF
Left dot indicator
= OFF
RUN LED
= RED
ERR LED
= RED
7-Segment display
= OFF
Right dot inicator
= OFF
Left dot indicator
= OFF
RUN LED
= GREEN
ERR LED
= OFF
7-Segment display
= FF
Right dot inicator
= OFF
Left dot indicator
= OFF
RUN LED
= GREEN
ERR LED
= OFF
7-Segment display
= FF
Right dot inicator
= OFF
Left dot indicator
= ON
RUN LED
= GREEN
ERR LED
= OFF
7-Segment display
= 00
Right dot inicator
= ON
Left dot indicator
= ON