  • Page 1 FirstCheck+ Instrument User Manual V2.1 FirstCheck+ 1000, FirstCheck+ 2000, FirstCheck+ 3000, FirstCheck+ 5000 Register your instrument online to receive your Extended 2 Year Warranty. See page 41 for details. FirstCheck+ Instrument User Manual part number: 820256...
  • Page 2 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Page 2 of 45...
  • Page 3: Declaration Of Conformity

    Potentially Explosive Atmospheres – Application of Quality Systems On behalf of Ion Science Ltd, I declare that, on the date this product accompanied by this declaration is placed on the market, the product conforms to all technical and regulatory requirements of the above listed directives.
  • Page 4: Table Of Contents

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Contents Declaration of conformity ......................3 Statements ........................... 5 Responsibility For Use ........................ 5 ! WARNINGS ! ........................... 5 ! CAUTIONS ! ..........................5 Quality Assurance ........................5 Disposal ............................
  • Page 5: Statements

    A few parts per million in air for an hour or two causes serious permanent damage to the sensor, to the extent that it will NOT work. Therefore any instrument such as Ion's Firstcheck+ should be kept well away from facilities where silicones are used.
  • Page 6: Legal Notice

    It is provided "as is" and without any representation, term, condition or warranty of any kind, either express or implied. To the extent permitted by law, Ion Science shall not be liable to any person or entity for any loss or damage which may arise from the use of this manual.
  • Page 7: Introduction To Firstcheck

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Introduction to FirstCheck+ FirstCheck+ is a portable gas detector, suitable for the detection of a large range of Volatile Organic Compounds (VOC's), Carbon Monoxide (CO ), Oxygen (O...
  • Page 8: Getting Started

    To avoid drawing dust or particulate matter into the detector cell we suggest always fitting the filter with the Ion Science logo facing away from the instrument, therefore dust only collects on the same one side of the filter and is not inadvertently drawn into the instrument if the filter is attached the other way round.
  • Page 9 The rate at which the batteries self discharge directly relates to the ambient temperature; the higher the ambient temperature, the quicker the discharge. Ion Science Ltd recommends charging the instrument for 12 hours before use (see the battery section of this manual „Batteries‟).
  • Page 10: Instrument Functions

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Functions Keypad function descriptions ON/OFF To switch the FirstCheck+ instrument ON - Press the ON/OFF key. To switch the FirstCheck+ instrument OFF – Firstly, ensure you are on the DISPLAY/FUNCTION Selection screen, or a DISPLAY screen.
  • Page 11 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Functions _____ Display/Function Selection Viewing Screens (14) (P 14 & 15) Zone Select (P 16) Data Transfer Application (P 16) Mode – H&S or Survey (p21) Alarm...
  • Page 12: Quick Reference Guide

    Allows the user to view detected VOC levels in either graph or number format and to adjust the instrument functions and parameters. Zone Selection (see „Instrument Menu‟) FirstCheck+ 2000, 3000 & 5000 Allows the selection of predefined Zone names so data logged information can be referenced to an application or area.
  • Page 13 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Quick Reference Guide Application (see „Instrument Menu‟) Allows the selection of modes of operation, „Health and Safety‟ for STEL and TWA monitoring or „Survey‟ for general use. Page 13 of 45...
  • Page 14: Instrument Displays

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Displays Display Screens Explained DISPLAY/FUNCTION Selection Screen The DISPLAY/FUNCTION selection screen is shown when the FirstCheck+ is first switched on, and can always be located by repeatedly pressing the ESC (Escape) key. The DISPLAY/FUNCTION screen allows the user to view gas levels in a variety of ways and also allows access to the Function menu where settings can be adjusted.
  • Page 15: Small Multiple Readout Screen

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Displays _____ Peak Hold Peak Hold is a numerical measurement that indicates the peak or maximum reading of that selected gas sensor and is displayed to the right of the above symbol. The Peak reading can be reset by pressing and...
  • Page 16: Instrument Menu

    FirstCheck+ instrument. Once a Zone is selected on the instrument, all data files will include that Zone name in the files header detail. To avoid long download times Ion Science recommends downloading data on a daily basis. The FirstCheck+ has a default Zone called Zone 0. Unless specified, all readings will automatically be stored in this Zone.
  • Page 17: Sound

    Custom General description Due to the linear output of the Ion Science PID detector, FirstCheck+ instruments only require a two-point calibration. The FirstCheck+ scales its linear output across a Zero level (clean air reference) and the Span (a user defined gas concentration).
  • Page 18 If performing a custom calibration using the Ion Science Calibration Kit accessory, you will need you use the Cal Adaptor supplied with your FirstCheck+ in the Cal Kit sample box.
  • Page 19 If you have chosen a mix this will be available on screen or a combination of both. Ion Science recommends that if you are using single gases to calibrate the sensors then it is done in the following order: VOC, LEL, CO then the H S.
  • Page 20: Back-Light

    WARNING!: Ion Science makes every effort to ensure the gas tables held within the FirstCheck+ memory and supplied on CD are accurate at the time of manufacture. In critical applications alarm levels must be checked, compared and adjusted to local legislation before use.
  • Page 21: Unit Selector

    Instrument Menu _____ WARNING: Ion Science makes every effort to ensure the gas tables held within the FirstCheck+ memory and supplied on CD are accurate at the time of manufacture. In critical applications alarm levels must be checked, compared and adjusted to local legislation before use.
  • Page 22: Application - Survey Mode

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Menu Application - Survey Mode 'SURVEY' is the default mode of operation whenever the 'Health & Safety' mode is NOT selected. All functions can be adjusted or selected in this mode unless the 'Security mode' is set via the 1stPC software.
  • Page 23: 1Stpc Software

    Before connecting your FirstCheck+ to a PC for the first time, check that the PC‟s IRDA works correctly with another device. Installation of 1stPC Software Insert Ion Science software CD into your CD drive. The CD will automatically start up. Click on the Download Software button.
  • Page 24 FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Ion Science Ltd 1stPC Software ______________ 1stPC software has many features allowing the transfer for data and function specifications to and from the instrument and the PC. Downloading data logged readings FirstCheck+ should always be presented to the IRDA port before the 1stPC software is run.
  • Page 25 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software ______________ The instrument has 8Mb of memory, which is divided into 1Mb segments. When a segment becomes full, data is then stored in the next segment.
  • Page 26 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software __________________ Data Data logged information can be cleared from your instrument or downloaded from the instrument to your PC. Once downloaded to your PC, files can be saved for future reference and exported as CSV files.
  • Page 27 An instrument upgrade allows you to upgrade your instrument to other FirstCheck+ variants with advanced features, once you have purchased the pass code from Ion Science. A Firmware upgrade allows you to upgrade your actual instrument software directly, should an upgrade be made available.
  • Page 28 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software Lamp Enables the selection of different lamp types you may have purchased to use with your instrument. If you have purchased the instrument with the 11.7eV lamp, there are a number of things related to applications that you must take into consideration before using the lamp.
  • Page 29 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software __________ Backlight Gives you the option of turning the back light on or off permanently, or setting it to come on for a specific time after every key press.
  • Page 30 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software _______________ Calibration The calibration settings can also be adjusted under the Menu Settings and uses the same layout as described on the „Instrument Menu‟ section. Once you have selected all of your settings, choosing the following options will transfer them to the instrument.
  • Page 31 Ltd discretion, to either (a) return of payment as evidenced by a copy of the Receipt, or (b) replacement of the disk that does not meet Ion Science Ltd limited warranty and which is returned to Ion Science Ltd with a copy of the Receipt.
  • Page 32: Batteries

    Ion Science Ltd Batteries Note: Ion Science recommends keeping your FirstCheck+ on charge at all times when not in use, as batteries can loose power over time. Loss of battery power can result in the instrument‟s charge indicator showing a non-charging status when trying to charge the unit. If this occurs, leave the charger connected for two minutes, then remove and reconnect the charger as soon the timer symbol disappears.
  • Page 33 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Batteries Replacement of Non-rechargeable batteries 1. Ensure the FirstCheck+ is switched Off. 2. Using the battery cover removal tool provided, remove the battery cover at the rear of the instrument casing. This reveals a set of 4 x AA cells contained in a removable battery clip.
  • Page 34: Diagnostics

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Diagnostics Basic faults or diagnostics are presented as symbols with a more detailed description of the fault indicated by the number in the top right hand corner of the display. Should a fault occur, correct the issue and then press ENTER or ESC to clear the fault message.
  • Page 35 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Diagnostics _____ Health & Safety When in Health & Safety mode the selected gas has no STEL or TWA alarm values. This provides a warning in Health & Safety mode that the change you are making could effect the ongoing calculations.
  • Page 36: Maintenance

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Maintenance Blowing out the PID Cell will fix 99% of maintenance problems When using the PID instrument in conditions of high ambient humidity, the PID may show unexpected readings appearing to increase.
  • Page 37: Use Of Pid Lamp Cleaning Kit A-31063

    USE of PID lamp cleaning kit A-31063 1. The vial of cleaning compound contains Aluminium Oxide as a very fine power (CAS Number 1344-28- 1). A full material safety data sheet MSDS is available on request from Ion science Ltd. The key issues are listed below: Hazard identification: ...
  • Page 38 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Maintenance _____ 3. Use this cotton bud to polish the PID lamp window. Use a circular action applying light pressure to clean the lamp window. Never touch the lamp window with fingers.
  • Page 39: Accessories

    FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Accessories Ion Science Ltd has developed an exclusive range of high quality accessories to compliment the FirstCheck+. Please refer to the table below for a selection of FirstCheck+ accessories. Part Number...
  • Page 40: Upgrade Options

    After ordering the upgrade for your instrument a code will be sent to you by e-mail. Use the 1stPC software to enter the code and your instrument instantly becomes the new version. Contact your local Ion Science distributor for pricing. Page 40 of 45...
  • Page 41: Instrument Warranty And Service

    Service Ion Science is pleased to offer a number of service options on our FirstCheck+ product range, allowing you to choose the cover for your instrument that best suits your needs. At Ion Science we recommend that all of our gas detection instruments be returned for service and factory calibration once every 12 months.
  • Page 42: Technical Specifications

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Technical Specifications Detector Range Response Time* PID (VOC detector) 1 ppb - 10,000 ppm (FirstCheck+ 5000) T90 < 1 second 0.1 ppm – 10,000 ppm (FirstCheck+ 3000) 0.1 ppm – 4,000 ppm (FirstCheck+ 1000 and 2000)
  • Page 43 Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Technical Specifications ___________ Expected lifetime of parts Batteries On the condition of normal use battery capacity will be reduced to approximately 70% after 250 full battery cycles or 1 year (whichever comes first).
  • Page 44: Update Log

    Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Update Log Manual Version Amendment Date Updated Instrument Firmware PC Software FirstCheck+ Add IS Protective Cover details 18/06/08 V2.04 V1.2 to manual – updated to V1.3 FirstCheck+ Add new software installation 24/10/08 V2.04...