Page 1
FirstCheck+ Instrument User Manual V2.1 FirstCheck+ 1000, FirstCheck+ 2000, FirstCheck+ 3000, FirstCheck+ 5000 Register your instrument online to receive your Extended 2 Year Warranty. See page 41 for details. FirstCheck+ Instrument User Manual part number: 820256...
Page 2
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Page 2 of 45...
Potentially Explosive Atmospheres – Application of Quality Systems On behalf of Ion Science Ltd, I declare that, on the date this product accompanied by this declaration is placed on the market, the product conforms to all technical and regulatory requirements of the above listed directives.
A few parts per million in air for an hour or two causes serious permanent damage to the sensor, to the extent that it will NOT work. Therefore any instrument such as Ion's Firstcheck+ should be kept well away from facilities where silicones are used.
It is provided "as is" and without any representation, term, condition or warranty of any kind, either express or implied. To the extent permitted by law, Ion Science shall not be liable to any person or entity for any loss or damage which may arise from the use of this manual.
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Introduction to FirstCheck+ FirstCheck+ is a portable gas detector, suitable for the detection of a large range of Volatile Organic Compounds (VOC's), Carbon Monoxide (CO ), Oxygen (O...
To avoid drawing dust or particulate matter into the detector cell we suggest always fitting the filter with the Ion Science logo facing away from the instrument, therefore dust only collects on the same one side of the filter and is not inadvertently drawn into the instrument if the filter is attached the other way round.
Page 9
The rate at which the batteries self discharge directly relates to the ambient temperature; the higher the ambient temperature, the quicker the discharge. Ion Science Ltd recommends charging the instrument for 12 hours before use (see the battery section of this manual „Batteries‟).
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Functions Keypad function descriptions ON/OFF To switch the FirstCheck+ instrument ON - Press the ON/OFF key. To switch the FirstCheck+ instrument OFF – Firstly, ensure you are on the DISPLAY/FUNCTION Selection screen, or a DISPLAY screen.
Page 11
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Functions _____ Display/Function Selection Viewing Screens (14) (P 14 & 15) Zone Select (P 16) Data Transfer Application (P 16) Mode – H&S or Survey (p21) Alarm...
Allows the user to view detected VOC levels in either graph or number format and to adjust the instrument functions and parameters. Zone Selection (see „Instrument Menu‟) FirstCheck+ 2000, 3000 & 5000 Allows the selection of predefined Zone names so data logged information can be referenced to an application or area.
Page 13
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Quick Reference Guide Application (see „Instrument Menu‟) Allows the selection of modes of operation, „Health and Safety‟ for STEL and TWA monitoring or „Survey‟ for general use. Page 13 of 45...
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Displays Display Screens Explained DISPLAY/FUNCTION Selection Screen The DISPLAY/FUNCTION selection screen is shown when the FirstCheck+ is first switched on, and can always be located by repeatedly pressing the ESC (Escape) key. The DISPLAY/FUNCTION screen allows the user to view gas levels in a variety of ways and also allows access to the Function menu where settings can be adjusted.
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Displays _____ Peak Hold Peak Hold is a numerical measurement that indicates the peak or maximum reading of that selected gas sensor and is displayed to the right of the above symbol. The Peak reading can be reset by pressing and...
FirstCheck+ instrument. Once a Zone is selected on the instrument, all data files will include that Zone name in the files header detail. To avoid long download times Ion Science recommends downloading data on a daily basis. The FirstCheck+ has a default Zone called Zone 0. Unless specified, all readings will automatically be stored in this Zone.
Custom General description Due to the linear output of the Ion Science PID detector, FirstCheck+ instruments only require a two-point calibration. The FirstCheck+ scales its linear output across a Zero level (clean air reference) and the Span (a user defined gas concentration).
Page 18
If performing a custom calibration using the Ion Science Calibration Kit accessory, you will need you use the Cal Adaptor supplied with your FirstCheck+ in the Cal Kit sample box.
Page 19
If you have chosen a mix this will be available on screen or a combination of both. Ion Science recommends that if you are using single gases to calibrate the sensors then it is done in the following order: VOC, LEL, CO then the H S.
WARNING!: Ion Science makes every effort to ensure the gas tables held within the FirstCheck+ memory and supplied on CD are accurate at the time of manufacture. In critical applications alarm levels must be checked, compared and adjusted to local legislation before use.
Instrument Menu _____ WARNING: Ion Science makes every effort to ensure the gas tables held within the FirstCheck+ memory and supplied on CD are accurate at the time of manufacture. In critical applications alarm levels must be checked, compared and adjusted to local legislation before use.
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Instrument Menu Application - Survey Mode 'SURVEY' is the default mode of operation whenever the 'Health & Safety' mode is NOT selected. All functions can be adjusted or selected in this mode unless the 'Security mode' is set via the 1stPC software.
Before connecting your FirstCheck+ to a PC for the first time, check that the PC‟s IRDA works correctly with another device. Installation of 1stPC Software Insert Ion Science software CD into your CD drive. The CD will automatically start up. Click on the Download Software button.
Page 24
FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Ion Science Ltd 1stPC Software ______________ 1stPC software has many features allowing the transfer for data and function specifications to and from the instrument and the PC. Downloading data logged readings FirstCheck+ should always be presented to the IRDA port before the 1stPC software is run.
Page 25
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software ______________ The instrument has 8Mb of memory, which is divided into 1Mb segments. When a segment becomes full, data is then stored in the next segment.
Page 26
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software __________________ Data Data logged information can be cleared from your instrument or downloaded from the instrument to your PC. Once downloaded to your PC, files can be saved for future reference and exported as CSV files.
Page 27
An instrument upgrade allows you to upgrade your instrument to other FirstCheck+ variants with advanced features, once you have purchased the pass code from Ion Science. A Firmware upgrade allows you to upgrade your actual instrument software directly, should an upgrade be made available.
Page 28
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software Lamp Enables the selection of different lamp types you may have purchased to use with your instrument. If you have purchased the instrument with the 11.7eV lamp, there are a number of things related to applications that you must take into consideration before using the lamp.
Page 29
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software __________ Backlight Gives you the option of turning the back light on or off permanently, or setting it to come on for a specific time after every key press.
Page 30
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd 1stPC Software _______________ Calibration The calibration settings can also be adjusted under the Menu Settings and uses the same layout as described on the „Instrument Menu‟ section. Once you have selected all of your settings, choosing the following options will transfer them to the instrument.
Page 31
Ltd discretion, to either (a) return of payment as evidenced by a copy of the Receipt, or (b) replacement of the disk that does not meet Ion Science Ltd limited warranty and which is returned to Ion Science Ltd with a copy of the Receipt.
Ion Science Ltd Batteries Note: Ion Science recommends keeping your FirstCheck+ on charge at all times when not in use, as batteries can loose power over time. Loss of battery power can result in the instrument‟s charge indicator showing a non-charging status when trying to charge the unit. If this occurs, leave the charger connected for two minutes, then remove and reconnect the charger as soon the timer symbol disappears.
Page 33
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Batteries Replacement of Non-rechargeable batteries 1. Ensure the FirstCheck+ is switched Off. 2. Using the battery cover removal tool provided, remove the battery cover at the rear of the instrument casing. This reveals a set of 4 x AA cells contained in a removable battery clip.
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Diagnostics Basic faults or diagnostics are presented as symbols with a more detailed description of the fault indicated by the number in the top right hand corner of the display. Should a fault occur, correct the issue and then press ENTER or ESC to clear the fault message.
Page 35
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Diagnostics _____ Health & Safety When in Health & Safety mode the selected gas has no STEL or TWA alarm values. This provides a warning in Health & Safety mode that the change you are making could effect the ongoing calculations.
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Maintenance Blowing out the PID Cell will fix 99% of maintenance problems When using the PID instrument in conditions of high ambient humidity, the PID may show unexpected readings appearing to increase.
USE of PID lamp cleaning kit A-31063 1. The vial of cleaning compound contains Aluminium Oxide as a very fine power (CAS Number 1344-28- 1). A full material safety data sheet MSDS is available on request from Ion science Ltd. The key issues are listed below: Hazard identification: ...
Page 38
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Maintenance _____ 3. Use this cotton bud to polish the PID lamp window. Use a circular action applying light pressure to clean the lamp window. Never touch the lamp window with fingers.
FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Accessories Ion Science Ltd has developed an exclusive range of high quality accessories to compliment the FirstCheck+. Please refer to the table below for a selection of FirstCheck+ accessories. Part Number...
After ordering the upgrade for your instrument a code will be sent to you by e-mail. Use the 1stPC software to enter the code and your instrument instantly becomes the new version. Contact your local Ion Science distributor for pricing. Page 40 of 45...
Service Ion Science is pleased to offer a number of service options on our FirstCheck+ product range, allowing you to choose the cover for your instrument that best suits your needs. At Ion Science we recommend that all of our gas detection instruments be returned for service and factory calibration once every 12 months.
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Technical Specifications Detector Range Response Time* PID (VOC detector) 1 ppb - 10,000 ppm (FirstCheck+ 5000) T90 < 1 second 0.1 ppm – 10,000 ppm (FirstCheck+ 3000) 0.1 ppm – 4,000 ppm (FirstCheck+ 1000 and 2000)
Page 43
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Technical Specifications ___________ Expected lifetime of parts Batteries On the condition of normal use battery capacity will be reduced to approximately 70% after 250 full battery cycles or 1 year (whichever comes first).
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Update Log Manual Version Amendment Date Updated Instrument Firmware PC Software FirstCheck+ Add IS Protective Cover details 18/06/08 V2.04 V1.2 to manual – updated to V1.3 FirstCheck+ Add new software installation 24/10/08 V2.04...
Page 45
Ion Science Ltd FirstCheck+ 1000, 2000, 3000 & 5000 Ion Science Ltd Page 45 of 45...