Acoustics; Test For Prominent Discrete Tones (Pdts); Electromagnetic Immunity - Seagate Skyhawk AI ST6000VE001 Product Manual

Table of Contents

Advertisement

www.seagate.com
2.7

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements are consistent with
ISO document 7779. Sound power measurements are taken under essentially free-field conditions over a reflecting plane. For all tests,
the drive is oriented with the cover facing upward.
For seek mode tests, the drive is placed in seek mode only.
The number of seeks per second is defined by the following equation:
Note
(Number of seeks per second = 0.4 / (average latency + average access time
Table 3
Fluid Dynamic Bearing (FDB) motor acoustics
Idle*
2.7 bels (typical)
2.8 bels (max)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification,
which may increase acoustic and power to operational levels.
2.7.1

Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is the use of the
absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-7) to discern tone audibility and to compensate
for the inaudible components of sound prior to computation of tone ratios according to Annex D of the ECMA-74 standards.
2.8

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in performance when
subjected to the radio frequency (RF) environments defined in
Table 4
Radio frequency environments
Test
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Voltage dips, interrupts
Seagate SkyHawk AI Product Manual, Rev. B
Seek
2.8 bels (typical)
2.9 bels (max)
Description
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @ 200Hz
± 1 kV on AC mains, ± 0.5 kV on external I/O
± 1 kV differential, ± 2 kV common,
AC mains
150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz sine
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
Table 4
.
Performance
level
B
A
B
B
A
C
C
C
B
Drive Specifications
Reference
standard
EN61000-4-2: 95
EN61000-4-3: 96
ENV50204: 95
EN61000-4-4: 95
EN61000-4-5: 95
EN61000-4-6: 97
EN61000-4-11: 94