Acoustics; Test For Prominent Discrete Tones (Pdts); Electromagnetic Immunity - Seagate ST12000VN0008 Product Manual

Hide thumbs Also See for ST12000VN0008:
Table of Contents

Advertisement

www.seagate.com
1.2.7

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All measurements
are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditions
over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
NOTE
)
Table 4 Fluid Dynamic Bearing (FDB) motor acoustics
All models
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification,
which may increase acoustic and power to operational levels.
1.2.8

Test for Prominent Discrete Tones (PDTs)

Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this process is
the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 389-7) to discern
tone audibility and to compensate for the inaudible components of sound prior to computation of tone ratios
according to Annex D of the ECMA-74 standards.
1.2.9

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5 Radio frequency environments
Test
Electrostatic discharge
Radiated RF immunity
Electrical fast transient
Surge immunity
Conducted RF immunity
Voltage dips, interrupts
Seagate IronWolf Serial ATA Product Manual, Rev. C
For seek mode tests, the drive is placed in seek mode only. The number of seeks
per second is defined by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time
Idle*
1.8 bels (typ)
2.0 bels (max)
Description
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
80 to 1000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
± 1 kV on AC mains, ± 0.5 kV on external I/O
± 1 kV differential, ± 2 kV common, AC mains
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
Performance seek
2.6 bels (typ)
2.8 bels (max)
Performance level
B
A
B
B
A
C
C
C
B
Drive specifications
Reference standard
EN 61000-4-2: 95
EN 61000-4-3: 96
ENV 50204: 95
EN 61000-4-4: 95
EN 61000-4-5: 95
EN 61000-4-6: 97
EN 61000-4-11: 94
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exos x14St14000vn0008512eSt10000vn0008