4.3.4 Releasing the Feed Unit

After finishing the drilling, the drive shall be released from top of the assembly. In lower pressures, this
can be done by hand. For higher pressures >12 bar it is highly recommended to use the chain block.
- Both of the the adjusting handles ③ shall be gripped, pushed
forward and simultaniously turned counter-
clockwise to release the adusting socket.
- The socket can now be reversed by sliding the power screws
completely off from the drill body
- Release the shaft completely. The chuck inside the drilling
chamber stopps the shaft from comming out.
Warning: If you are unsure about the forces acting on the
shaft while releasing it, use the chain block for this operation.
From the manufacturers experience, it is advisable to use it at a
pressure >12 bar. See chapter 4.6 how to use the chain block.

4.3.5 Closing the Valve and Releasing the Pressure

- The valve has to be closed completely by turning the
ball using proper allen key and turning it 90 degrees.
Since the ball in the hot tap valve has no automatic
stop, you may have to adjust the position
of the ball until it is in correctly closed position.
- The tightness can be controlled by opening the
control cock.
- Connect the hose to the control cock and open it to
release the pressure
CAUTION: Keep enough distance to the
hose while releasing the
pressure to protect yourself.
Make sure the valve is
completely closed !
18 | VI.KD.G1.02
JIP Hot Tapping Machine