DHD Controller: If your VX-6000d is equipped with a CineWide with AutoScope system,
connect the AutoScope lens motor to a 12-volt trigger output on the DHD Controller; see
Figure 3-17.
Similarly connect other 12-volt trigger-activated equipment (such as retractable screens or
screen masks) to the other trigger outputs.
For more information on using the DHD Controller triggers, refer to Triggers on page 70.
AutoScope Lens Motor
Power
AC Input
Switch
3.5-mm
mini plug
Retractable Screen or other
12-volt trigger-activated
device
Figure 3-17. 12-volt Trigger Output Connections (from DHD Controller)
Runco VX-6000d Installation/Operation Manual
Sleeve = Ground
Tip = +12V
39
Installation
Connecting 12-volt
Trigger Outputs to
External Equipment