Emi And Environmental Type Tests - RuggedCom RuggedWireless RS900W Specification Sheet

Ruggedcom ruggedwireless wireless ethernet with integrated 8-port managed switch specification sheet
Hide thumbs Also See for RuggedWireless RS900W:
Table of Contents

Advertisement

Test
TS-2 1998, Section 2, para 2.2.7.3
TS-2 1998, Section 2, para 2.2.7.4
TS-2 1998, Section 2, para 2.2.7.5
TS-2 1998, Section 2, para 2.2.7.6
TS-2 1998, Section 2 para. 2.2.8.4
TS-2 1998, Section 2, para 2.1.10
TS-2 1992, Section 2, para. 2.1.6.1
TS-2 1998, Section 2 para. 2.1.6.2
TS-2 1998, Section 2, para 2.1.7
TS-2 1992, Section 2, para. 2.1.8
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
Burst (Fast Transient)
IEC 61000-4-5
IEC 61000-4-6
Induced (Conducted) RFI
IEC 61000-4-8
Magnetic Field
IEC 61000-4-11
IEC 60255-5
Dielectric Strength
IEC 60255-5
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
Notes: 1. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")
www.RuggedCom.com

EMI and Environmental Type Tests

NEMA TS-2 Requirements
Description
Temperature: Low Temperature/Low
Voltage
Temperature: Low Temperature/High
Voltage
Temperature: High Temperature/High
Voltage
Temperature: High Temperature/Low
Voltage
Vibration Endurance Test
Mechanical Shock
Electrical Transients: High Repetition Noise
(AC Terminals)
Electrical Transients: Low-Repetition High
Energy (AC Terminals
Electrical Transients: I/O Terminals
Electrical Transients: Nondestruct
Transient Immunity (AC Terminals)
IEC 61000-6-2 EMC Generic Standard: Immunity for Industrial Environments
Description
Enclosure Contact
ESD
Enclosure Air
Radiated RFI
Enclosure ports
Signal ports
D.C Power ports
A.C. Power ports
Signal ports
Surge
D.C Power ports
A.C. Power ports
Signal ports
D.C Power ports
A.C. Power ports
Earth ground ports
Enclosure ports
Voltage Dips
A.C. Power ports
Signal ports
D.C. Power ports
A.C. Power ports
Signal ports
H.V. Impulse
D.C. Power ports
A.C. Power ports
Description
Cold Temperature
Dry Heat
Humidity (Damp Heat, Cyclic)
Vibration
Shock
Wireless Ethernet with Integrated 8-Port Managed Switch
Levels
89.0 VAC @ -34°C
135.0VAC @ -34°C
135.0VAC @ + 75°C
89.0VAC @ + 75°C
0.5g @ 30Hz for 1hr on all three planes
+/-10g half sine wave for 11msec on all
three planes
One +/-300VDC pulse every other cycle
once every 3 seconds across 360 ° of line
cycle (2500W peak)
One +/-600VDC pulse every second, ran-
domly distributed across 360 ° of line
cycle. Ten pulses total.
One +/-300VDC pulse every second, mini-
mum 5 pulses per port
One +/-1000VDC pulse every two seconds,
3 per each polarity.
Levels
+/- 4kV
+/- 8kV
10 V/m, 80 to 1000Mhz
+/- 1kV @ 5kHz
+/- 2kV @ 5kHz
+/- 2kV @ 5kHz
+/- 1kV line-to-earth
+/- 0.5kV line-to-earth/line
+/- 2kV line-to-earth, +/- 1kV
line-to-line
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
30 A/m @ 50, 60 Hz
30% reduction for 0.5
period
>95% reduction for 250
periods
2kVac
(Fail-Safe Relay output)
2kVac
2kVac
5kV
(Fail-Safe Relay output)
5kV
5kV
Environmental Type Tests
Test Ad
Test Bd
Test Db
Tests Fc
Tests Ea
RuggedWireless
Performance Criteria*
EUT Continued to function properly during
and following all temperature and humidity
EUT functioned properly following test pro-
cedure. No physical damage.
EUT functioned properly following test pro-
cedure. No physical damage.
EUT functioned properly during and follow-
ing test procedure. No damage
EUT functioned properly during and follow-
ing test procedure. No damage
EUT functioned properly during and follow-
ing test procedure. No damage
EUT functioned properly following test pro-
cedure. No damage
RuggedCom Test Level
+/- 8kV
+/- 15kV
20V/m
+/- 4kV @ 2.5kHz
+/- 4kV
+/- 4kV
+/- 2kV line-to-earth, +/- 2kV
line-to-line
+/- 4kV line-to-earth, +/- 2kV
line-to-line
+/- 4kV line-to-earth, +/- 2kV
line-to-line
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
10V @ 0, 5-80 MHz
40 A/m continuous, 1000
A/m for 1s
30% for 1 period
100% for 5 periods, 100%
for 50 periods
2kVac
(Fail-Safe Relay output)
2kVac
2kVac
5kV
(Fail-Safe Relay output)
5kV
5kV
Test Levels
-40°C, 16 Hours
+85°C, 16 Hours
95% (non-condensing),
55°C , 6 cycles
2g @ (10 - 150) Hz
30g @ 11mS
RuggedWireless™ RS900W
TM
RS900W
testing
Performance Criteria*
B
B
A
B
B
B
B
B
B
A
A
A
A
A
B
C
N/A
N/A
N/A
N/A
N/A
N/A
Severity Levels