b. Numeric-Entry Edit.
Key Pad:
Typing any character on the numeric keypad
will set up a 'box' beneath a smaller version of
the selected numeric value, and place the typed
character in the box. The right side key labels
change to give a choice of units.
Units:
After the new value has been typed on the
keypad, the required units can be chosen from
the right side soft keys. Pressing one of these
keys will cause the display to revert to the 'Digit
Edit' format, with the same numeric value
remaining selected by the two triangles.
'Enter':
The keypad 'Enter' (ø) key can be used instead
of one of the units keys to revert to 'Digit Edit'
format. In this case the 9500B firmware will
always impose the basic units (not multiples or
sub-multiples).
Further Use: Either Digit Edit or Numeric-Entry Edit can be
used for all selectable variables on the screen.
Function
'Barred'
Selection
Cursor
Numeric
Output
Values
Output
Value
Units
Descriptions assume 9500B/1100
Selected SIGNAL
Selected TRIGGER
Channel
'No Trigger' State
Output
Icon
State
SIGNAL
OFF
TRIGGER
5.ØØ mV/div x4
= 2Ø.ØØØ mV
Deviation = ØØ.ØØ %
O/P Amplitude = 2Ø.ØØØ mV
Frequency = 1.ØØØØ kHz
TODAY'S DATE
TIME
WAVE
FORM
Soft key label
Accesses
(Toggle)
not used with
Waveform
Applies
DC/Square
Menu
Ground
Default
Condition
Screen
(O/P On)
Fig. 3.2.1 Manual Mode — Startup Default Settings
3. Scope Mode
This mode differs from Direct Mode only in that adjustment of
many screen variables is constrained to a series of 'Stepped Values',
which run in a sequence of 1 : 2 : 5 factor steps (The 'Pref' facility,
described overleaf, can be used to change the factor sequence to
match certain oscilloscopes with 1 : 2 : 2.5 : 4 : 5 steps). Selecting
one of these variables places a 'barred' cursor above and below the
whole numeric value (shown in Fig 3.2.1), and only one method of
value adjustment is available:
Cursor keys:
These forms of editing are also described in greater detail, with
illustrations, in Section 4, sub-section 4.4.
Expected Load
Channel or
Impedances
CH1
5ØΩ
x 1Ø
CH5
5ØΩ
pk-pk
∆ = Ø
pk-pk
1 2
CHANNEL
1.Ø
SELECT
5
Toggles
Accesses
to Select
Channel
'Scope' or
Selection
Menu
'Direct Entry'
Mode
Section 3: Model 9500B Controls: Modes of Operation
1 2
1.Ø
5
and
are not used. Adjustment is
carried out using the
spinwheel) to increment or decrement the whole
value through the pre-defined factor steps.
Multiplies Selected
Value by 10
Divides Selected
Value by 10
Toggles Deviation between
zero and previously set value
These three soft key
labels not used with
the DC/Square
Default Screen
Uses of all the right side
soft key labels are
Screen
dependent on the field
Key
selected on the main part
Effects
of the screen
All bottom soft key labels
may be employed for
alternative or additional
selections
and
keys (or
3-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents