2.2
Installation Procedures
Using N4 (90 x 205 mm) or N3 (120 x 235 mm) Envelopes
The following parts need to be installed when N4 or N3 envelopes are used.
-
Bottom auxiliary guide assy [A] (1 piece)
-
Adjusting block assy (2 pieces)
-
Side auxiliary guide assy [B] (2 pieces)
-
Guide shaft (1 piece)
1
Open the upper door.
2
Remove the holding paper.
% Hold the projection with your fingers and slide the hold-
ing paper in the arrowed direction, and remove it.
3
Install the bottom auxiliary guide assy [A] in the Large Ca-
pacity Unit LU-202m/LU-202XL/LU-202XLm tray.
% Align the positioning pin of the bottom auxiliary guide
assy [A] with the installation hole of the tray.
% Align the detent of the bottom auxiliary guide assy [A]
with the groove on the back end guide.
4
Align the adjusting block assies (2 pieces) to N4 and N3 on
the indicating label, and install them.
% Align the mark on the adjusting block assy with the
mark on the indicating label.
AccurioPress C3080/C3080P/C3070, AccurioPrint C3070L
N4 (90 x 205 mm), 
N3 (120 x 235mm)