Fusing unit
Hide thumbs Also See for AccurioPress C3080:
Table of Contents

Advertisement

2.2
Installation Procedures
5
Pull out the fixing plate [1] forward.
6
Holding the handles on the rear and front sides [2] of the
fusing unit [1] by both hands, slide the fusing unit [1] for-
ward to the position of arrow mark.
Please be careful when working on the fusing unit; the unit
is extremely hot.
7
Holding the handles on the rear and front sides [2] of the
fusing unit [1] by both hands, remove the fusing unit [1].
Place the removed fusing unit on the flat surface.
8
Holding the handles on the front and rear sides [2] of Fus-
ing Unit EF-103 [1] with both hands, set Fusing Unit EF-
103 [1] on the fixing position with arrow mark.
NOTICE
Make sure that the exit section is open before setting Fus-
ing Unit EF-103 to the machine. When you try to set the
fusing unit with the exit guide unit closed, the machine may
be damaged.