Mounting the
Water Heater
•
It is recommended as per IS302-1 to have
6 inches clearance from wall.
•
Select a place to mount Water Heater
vertically with water connection at the
bottom.
Figure 6
Ceiling
6 inch
Water Heater
•
Use a drill bit with diameter of 12 mm to
drill 2 holes at least 90 mm deep in the wall
(Fig. 8 : Step 3). The two holes should be
aligned horizontally. The horizontal
distance between the 2 holes should be
74 mm (Fig. 8 : Step 2).
Figure 8
1
2
Drilling
Tool
Wall
6 inch
90 mm
3
Concrete
Concrete
Hole
Wall
Wall
7
•
Water heater must be located within
3-1/2 ft. (approx.) from a 230V electrical
outlet with proper grounding.
•
Make sure that the wall can withstand at
least twice the weight of the Water Heater
when completely lled with water.
Figure 7
Solid
Solid
Concrete
Concrete
Wall
Wall
•
Insert the Expansion Anchor into the hole
(Fig. 9 : Step 1).
•
Place the Hanging Screw over the
Expansion Anchor and tighten the Hanging
Screw by rotating it till it gets xed steadily
(Fig. 9 : Step 2).
Figure 9
1
Concrete
Concrete
Wall
Wall
2
Concrete
Concrete
Wall
Wall
3-1/2 ft.
False
False
Wall
Wall
Expansion
Expansion
Anchor
Anchor
Hole
Hanging
Hanging
Screw
Screw