Finishing; Facing Material; Finishing A. Facing Material - Outdoor Lifestyles ODCOUG-36T Installation Manual

Hide thumbs Also See for ODCOUG-36T:
Table of Contents

Advertisement

7

Finishing

A. Facing Material
The fireplace structure can be covered with any
non-combustible material. Refer to Section 1.D.
WARNING! Risk of Fire! DO NOT apply
combustible materials beyond the minimum
clearances. Comply with all minimum clearances
to combustibles as specified in this manual.
Overlapping materials could ignite. Any installation
outside the scope as stated in this manual please
contact you authorized HHT dealer prior to
installation.
Figure 7.1. Minimum vertical and maximum horizontal mantel dimensions for combustible materials.
20
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Courtyard Installation Manual • 4608-901 Rev. A • 02/18
Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all
minimum clearances to combustible as specified.
Framing or finishing material closer than the
minimums listed must be constructed entirely
of non-combustible materials (i.e. steel studs,
concrete board, etc.)
Figure 7.1 and 7.2 show the dimensions for
mantels or other combustible projections above
the appliance opening.
12in.
305mm
8in.
203mm
6in.
152mm
2½in
63½mm
22 in.
559 mm
20 in.
508 mm
18 in.
457 mm
36 in. (914mm)
minimum to
ceiling
24 in.
610mm