Service Code
Reason
Family
(Platform specific)
WP BLDC motor not connected
WP BLDC ADC fault
(DIVA2 only)
WP BLDC over temp
(PB100 only)
WP/DP BLDC overload
(PB100 only)
WP/DP current plausibility
(PB100 only)
DP BLDC over current HW
(PB100 only)
DP BLDC over current SW
(PB100 only)
DP BLDC motor not following
(PB100 only)
DP BLDC motor not connected
60
Heating problem
Heating – over temperature
Heater relay problems
70
NTC problem
80
Auto Door Opener malfunction
Auto
Door
Opener
warning
Water Reuse Valve warning
90
Checksum mcf
Checksum ccf
Checksum UIdata
UI data version mismatch
UI data checksum mismatch
Technical Support – A.R.
Alarm Codes
Type
User visible
indication
abort
Yes
abort
Yes
stop
Yes
Please OBSERVE that i5A has different meaning depending on platform
abort
Yes
i5b (i5H)
abort
Yes
abort
Yes
abort
Yes
abort
Yes
abort
Yes
warning
No
Nothing
abort
No
abort
No
warning
No
Nothing
abort
Yes
timeout
warning
No
Nothing
warning
No
Nothing
inactive
No
Nothing
Nothing
inactive
No
inactive
No
Nothing
warning
No
Nothing
warning
No
Nothing
599 79 76 - 53 REV 1.0
User
failure
code read
i58
i58
Cycle will be terminated and electronic switched to reset on-condition
i59
i59
Cycle will be terminated and electronic switched to reset on-condition
i5A
i5A
Cycle stop and continuous automatically after problem solved – rta off
i5A
i5A
Cycle will be terminated and electronic switched to reset on-condition
i5b (i5H)
Cycle will be terminated and electronic switched to reset on-condition
i5C
i5C
Cycle will be terminated and electronic switched to reset on-condition
i5d
i5d
Cycle will be terminated and electronic switched to reset on-condition
i5E
i5E
Cycle will be terminated and electronic switched to reset on-condition
i5F
i5F
Cycle will be terminated and electronic switched to reset on-condition
i60
Heating element will be switched off for the rest of the cycle
i61
i61
Cycle will be terminated and electronic switched to reset on-condition
i62
i62
Heating element will be switched off for the rest of the cycle
i70
Heating element will be switched off for the rest of the cycle
i80
i80
Cycle will be terminated and electronic switched to reset on-condition
i81
Auto Door Opener tries to recover. If that fails, the cycle continues
i82
Cycle continues regardless the error
i91
Electronic functionality blocked – all off
i92
Electronic functionality blocked – all off
i93
Electronic functionality blocked – all off
i94
No update of UI configuration data is possible
i95
No update of UI configuration data is possible
Action in case of failure happens
without auto door opener
Dishwashers before
March 2017
User indication
i50
i50
i50
i50
i50
i50
i50
i50
i50
Nothing
i60
i60
Nothing
i80
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing
Nothing