4. Components Capacitor The circulation pump is connected to a capacitor. 2,0 μF for UK 2,5 μF for Europe Pressure Switch The pressure switch controls the water level. Without water, contact is closed. Adjusting: Turning the marked screw clockwise level Turning the marked screw anti clockwise level Heating element...
53°C Overheating protection (normally closed) opens at 83°C closes at 0°C Electronic EDW 503 On electronic models, a micro processor controls all components, this is done using triacs. The electronic also memorizes all programme data. The heating is switched by a relay on the electronic board.
Detergent dispenser Coil resistance 3000 Ohm Rinse aid dispenser Rinse agency capacity 140 ccm Solenoid coil resistance 1900 Ohm Inlet valve Capacity, max, 4 l/min Resistance 4800 Ohm Anti flood switch If the anti flood swich in the base tray is activated, all components are switched off except the drain pump Spares Operation - R.Kurzke 11/06 - 7 -...
Water softening system Operation of the water softening system When water is admitted, the inlet valve (1) opens and the hard water flows down into the ion exchanger (5), through which it flows and is softened before flowing through the water inlet (6) and then being sprayed into the Washing chamber.
5. Position of components upper panel Door opener Inner door Outer door Door seal EDW 503 Panel - 9 - Spares Operation - R.Kurzke 11/06 599 528 133 EN...
Page 10
Housing Coil for detergent dispenser Rinse-aid dispenser Door switch Basek rails Coarse sieve Interference filter Fine strainer Heating element Thermostats Base plate - 10 - Spares Operation - R.Kurzke 11/06 599 528 133 EN...
Water Inlet The water flows into the regeneration dosage chamber via inlet valve, over air break, into regeneration dosage chambers and into softener The level control container operates the pressure switch. Spares Operation - R.Kurzke 11/06 - 14 - 599 528 133 EN...
Rinsing system The function of the rinsing system is to wet the dishes loaded into the machine. The electric motor of the circulation pump is delivered with the impeller fitted to it. Half the pump casing forms part of the plastic chassis, CERAMIC NUT and the other half is bolted in position inside the SPRAY TUBE...
Strainer system The strainer system is one of the systems which are most important to the performance of the dishwasher. The design of this system is largely decisive to whether the dishwasher will be able to perform its most fundamental task: to wash the dishes clean. The strainer system must trap particles of food, etc.
10. Level control system There are two basic ways of metering the right amount of water into a dish-washer. The first is to open the inlet valve for a certain predetermined period of time, while the other is to use some means for measuring the water level in the machine.
11. Drain system The system consists of inner and outer drain hoses and a drain pump, and its function is to transport the contaminated water as efficiently as pos-sible from the machine to the waste water system of the buildin The drain pump is connected to the chassis at the coarse strainer and is sealed with an O-ring.
12. Regeneration The water chamber for regeneration contains 350 ml water. During regeneration, the regeneration valve is energized. The 350 ml water runs into the salt container and mixes with the salt to form a brine solution. In the top of the salt container there is an opening with a small filter, from here the brine solution enters the softener where the resins are regenerated.
13. Thermostats The thermostats are pressed into the tubular mountings in the plastic chassis. They measure the temperature on the outside of the plastic wall, which leads to a certain difference between the water temperature thermostat temperature. However, the specifications of the thermostats take this into account.
In addition, two overheating protections are incorporated into the element, i.e. one at each connection end. These are designed so that they will burn off if the element is switched on but has no cooling water around it. EDW 503 Spares Operation - R.Kurzke 11/06 - 21 - 599 528 133 EN...
16. Service Informations Coarse filter The purpose of the coarse filter is to catch large objects. Make sure that the filter is always clean. Fine filter It is just important to keep this filter clean. The fine filter can easily be lifted out for cleaning when the coarse filter is removed at first.
All components from the left and right side are now accessible. Rinse-aid dispenser Coil for Softener anti-siphon valve detergent dispenser Pressure switch Air chamber Electronic EDW 503 Thermostats Interference filter Drain pump Spares Operation - R.Kurzke 11/06 - 27 - 599 528 133 EN...
Remove the base plate The base plate of the machine is held with screws on the lower panel and at the bottom. Lay the machine on its back and lift off the base plate. It contains the bosses for the overflow water and the flooding switch. After removal you come to the most important functional components.
Outer and inner door They snap together and are held by plastic latches, on the under side. They can easily be unsnapped Replacement of the components within the door. After removing these screws, door handle detergend dispenser flap can be removed from the inner door.
To remove the inner door Remove the lower panel and the outer door. Open the door and remove the four screws (two on each side) securing the rack rails. Open the door to an angle of about 130° and carefuly relese the hinge pin on the right hand side. On the left hand side, the hinge pin is inserted in a hole without slot.
Remove this screw to dismount the rinse aid dispenser unit The coil with tappet as support for the detergent dispenser is held by two screws. - 32 - Spares Operation - R.Kurzke 11/06 599 528 133 EN...
The pressure monitor is simply screwed. The motor capacitor is screwed by a nut. Anti-siphon valve The air should be able to enter the hose from the Level control holder - not the other way around! container The take-off hose ventilation can be unscrewed (Air chamber) for cleaning when necessary, in case these rubber Remove the srew to lift off...
Heater element After the removal of the nut and the heater clip in the sump under the fine strainer, the heater element can be drawn forward through the chassis opening to remove.. - 34 - Spares Operation - R.Kurzke 11/06 599 528 133 EN...
Thermostats The mounting for the thermostats is screwed at the right side of the air chamber. After its release, the thermostats can be removed. Switch unit The switch unit is secured by means of screws and easily to remove. Float switch The float switch is snapped out with a small screwdriver and can be taken out of its mounting.
Circulation pump After loosening the screws of the holder, the circulation pump can be taken out of the pump chamber. Drain pump To dismount the drain pump, the hose clamps are released and the screws removed. After removing the drain pump Here you can see how the hose clamps can be re-tensioned with the tubing-bow with seals,...
Softener 1 To dismount the water softener, these attachment screws are removed. 2 The connections on the reed switch are removed. 3 The hose connections are detached. 4 The large nut of the salt hol der must be released . 5 A spanner is useful in removing the recycling inlet nut.
Leakages. Service solutions: Take of the cover to be able to see the Container on the left hand side. Let the dishwasher take in water and check the level. If the level is too high (leakage through the top of the Container) adjust the pressure level switch check assembling ofthe Container to tub, misaligned oring or screw not tightened.
Page 39
Check the locknut under the salt cap to ensure it is fully tightened. It should not be possible to unsrew by hand. In the case of leakage, here more checkpoints - 39 - Spares Operation - R.Kurzke 11/06 599 528 133 EN...