M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#8925
SP on 1st part sys
Select which spindle to display in the 1st part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
---Setting range---
High-order (Select an upper side spindle.): 0 to 8
Low-order (Select a lower side spindle.): 0 to 8, F
#8926
SP on 2nd part sys
Select which spindle to display in the 2nd part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
---Setting range---
High-order (Select an upper side spindle.): 0 to 8
Low-order (Select a lower side spindle.): 0 to 8, F
#8927
SP on 3rd part sys
Select which spindle to display in the 3rd part system window for the 2-, 3- or 4-part system simultaneous
display.
(Note 1) If you select "00" for the 2-, 3- or 4-part system simultaneous display, the default display is used (1st
spindle on the upper side and 2nd spindle on the lower side).
(Note 2) If you set the same number as, or a greater number than the setting of "#1039 spinno", or if the high-
or low-order setting is "0", the 1st spindle is displayed.
(Note 3) If you set the low-order to F, the screen shows the actual rotation speed, command speed and load
meter of the high-order spindle.
Note that for the 4-counter display in 4-part system simultaneous display, even if the low-order is not
F, the screen shows the actual rotation speed, command speed and load meter of the high-order
and low-order spindles.
(Note 4) [M8] 3- or 4-part system simultaneous display is enabled for a 15- or 19-type display unit only.
[C80] 3- or 4-part system simultaneous display is not available.
---Setting range---
High-order (Select an upper side spindle.): 0 to 8
Low-order (Select a lower side spindle.): 0 to 8, F
299