M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#9114
DEV0 FEED CHR.
[M8]
Set the length of the tape feed to be output at the start and end of the data during tape output.
---Setting range---
0 to 999 (characters)
#9115
DEV0 PARITY V
[M8]
Select whether to perform the parity check for the number of characters in a block at the input of data.
At the output of data, the number of characters is always adjusted to for the parity check.
0: Not perform parity V check
1: Perform parity V check
#9116
DEV0 TIME-OUT (sec)
[M8]
Set the time out time to detect an interruption in communication.
Time out check will not be executed when set to "0".
---Setting range---
0 to 30 (s)
#9117
DEV0 DR OFF
[M8]
Select whether to enable the DR data check in data I/O mode.
0: Enable
1: Disable
#9118
DEV0 DATA ASCII
[M8]
Select the code of the output data.
0: ISO/EIA code (Depends on whether #9113, #9213, #9313, #9413 or #9513 EIA output parameter is set
up.)
1: ASCII code
#9119
DEV0 INPUT TYPE
[M8]
Select the mode for input (verification).
0: Standard input (Data from the very first EOB is handled as significant information.)
1: EOBs following the first EOB of the input data are skipped until data other than EOB is input
#9120
DEV0 OUT BUFFER
[M8]
Select the buffer size of the output data which is output to output device using NC side serial port.
If the output device has a data receiving error (overrun error), decrease the buffer size with this parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 bytes
3: 8 bytes
4: 16 bytes
5: 64 bytes
233
IB-1501279-H