M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#9128
DEV0 EIA CODE !
[M8]
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "!".
When output with EIA code, data can be output using the alternate code in which the special ISO code, not
included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9201
DEV1 DEVICE NAME
[M8]
Set the device name corresponding to the device No.
Set a simple name for quick identification.
---Setting range---
Use alphabet characters, numerals and symbols to set a name within 3 characters.
#9202
DEV1 BAUD RATE
[M8]
Select the serial communication speed.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
#9203
DEV1 STOP BIT
[M8]
Select the stop bit length used in the start-stop system.
Refer to "#9204 DEV1 PARITY CHECK". At the output of data, the number of characters is always adjusted
to for the parity check.
1: 1 (bit)
2: 1.5
3: 2
#9204
DEV1 PARITY CHECK
[M8]
Select whether to add a parity check bit to the data.
ON
OFF
Start bit
Set this parameter in accordance with the I/O device specifications.
0: Not add a parity bit in I/O mode
1: Add a parity bit in I/O mode
#9205
DEV1 EVEN PARITY
[M8]
Select whether even or odd parity will be used when parity is used. This parameter is ignored when no parity
is added.
0: Odd parity
1: Even parity
1character
b1 b2 b3 b4 b5 b6
bn
Data bit
Parity bit
Stop bit
235
IB-1501279-H