M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
15.8 Computer Link Parameters [M8]
#9601
BAUD RATE
[M8]
Select the rate at which data is transferred.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
8: 38400
#9602
STOP BIT
[M8]
Select the stop bit length used in the start-stop system.
Refer to "#9603 PARITY EFFECTIVE". At the output of data, the number of characters is always adjusted to
for the parity check.
1: 1 (bit)
2: 1.5
3: 2
#9603
PARITY EFFECTIVE
[M8]
Select whether to add the parity bit to the data.
The parameter is set when using a parity bit separately from the data bit.
ON
OFF
Start bit
Set this parameter according to the specifications of input/output device.
0: Not add a parity bit at the input/output
1: Add a parity bit at the input/output
#9604
EVEN PARITY
[M8]
Select odd or even when parity is added to the data. This parameter is ignored when no parity is added.
0: Odd parity
1: Even parity
#9605
CHR. LENGTH
[M8]
Select the length of the data bit.
Refer to "#9603 PARITY EFFECTIVE".
0: 5 (bit)
1: 6
2: 7 (NC connection not supported)
3: 8
IB-1501279-H
1character
b1 b2 b3 b4 b5 b6
bn
Data bit
Parity bit
Stop bit
270