12 Program Errors (P)
P235
Program editing
Details
Operation was attempted for the file under program editing.
Remedy
Execute the program again after completion of program editing.
P240
No spec: Variable commands
Details
A variable command (with #) was issued though it is out of specifications.
Remedy
Check the specifications.
P241
No variable No.
Details
The variable No. commanded is out of the range specified in the specifications.
Remedy
Check the specifications.
Correct the program variable No.
P242
= not defined at vrble set
Details
The "=" sign has not been commanded when a variable is defined.
Remedy
Designate the "=" sign in the variable definition of the program.
P243
Can't use variables
Details
An invalid variable has been specified in the left or right side of an operation expression.
Assignment to a write-protected variable has been commanded.
Remedy
Correct the program.
P244
Invalid set date or time
Details
Date or time was set earlier than current date or time in the system variables (#3011, #3012) when the system
lock was valid.
Remedy
Date or time cannot be changed.
Correct the program.
P245
Tool No. error
Details
Tool data read/write command has been executed without selecting the tool command method.
Tool command method (#68000) or tool selection No. (#68001) is incorrect.
(1) The tool specified as "Tool in use" is not installed.
(2) Any unregistered tool No. has been designated.
(3) Tool selection No. (#68001) has not been designated.
Write of "Tool No." has been commanded using #68001 while tool No. is being designated.
Write of "Tool No." has been commanded for an already registered tool No.
Remedy
Check the program to make sure that the tool command method (#68000) and tool selection No. (#68001)
are correct.
Make sure, if you wish to designate a tool in use, that the said tool No. is nonzero and is already registered
on the tool management screen.
Make sure, if you wish to designate a tool No., that the tool No. registered on the tool management screen
has been commanded using #68001.
#68001 is unable to write the same tool No. as that already registered on the tool management screen.