Chrysler 1956 Imperial Service Manual page 28

Table of Contents

Advertisement

500
AMPERE
CARBON PILE RHEOSTAT
TO 300 AMPERE
METER
TO
STARTER
RELAY
...... -
..
GROUND
56x78
fig,
2
-
Te~'
Connection tor Battery
Capacity
A
battery that
has
a specific gravity reading
t
hat varies
more
than
30
points
between any
two
cells should
be replaced
and tested
for
cause
of failures,
Battery Voltage Test
The
Battery
Cell
Tester (Open·Circuit Volt·
meter) "OCV" testers are designed to test bat·
teries which
range
from
1.260
to
1.280 specific
g
ravity
when fully charged at 80
degrees F,
The "OCV" meter consists of
an
accurate
expanded.scale voltmeter equipped
with
test
prods
which are contacted to the
terminals
of
each cell,
To
make the battery test, contact the
meter
prods to the
proper
cell terminals
(red
to posi-
tive
,
black to negative)
,
using caution
not
to
prod across more than one
cell.
In the case of the 12·volt battery -
buried
link
s
- the
point
of the prod will have
to
be
pushed through the sealing compound to make
contact with the buried link for each cell reading,
NOT
E:
: F1'eshly charged
batte1'ies
have a "sm'·
fac
e cha1'ge" which causes high and inacc1l1'ate
readings unless properly dissipated,
If
battery
is in
the vehicle, turn headlights on ft'Om
1
to 3
min
u
tes to remove the surface charg
e,
26
The
individual
cell
readings
should be even
within
,015 volt. A battery
that shows readings
of
more
than
,015
volt
between
any two cells
should
be replaced,
Satisfactory
capacity tests
can be made only
when
the battery
equals
or exceeds
1.225
spe·
cific gravity
at
80
degrees F,
The high rate
equipment especially designed
for
12-volt
bat-
teries should be used,
Connect a carbon
pile rheostat
in series with
an ammeter
and the
battery, as shown in Fig-
ure
2,
CAUTION: Be sure the ca1'bon pile contml
knob is rotated to the full
resistance
position
before connecting,
NOTE:
The
voltmeter clips must only contact
the battn'y poMs and not the high rate dis-
cha1'ge tester clips; unless
t
his is done, the
actual ba,ttenl fer'lninal voltage -n'iIl
n
ot be in·
dicated,
Rotate
the carbon
pile
control
knob until
200
amperes registers
on the
meter,
With a battery
under
discharge
for approximately
30 seconds,
read terminal voltage,
If
terminal voltage
shows
9.0
volts or more, the battery has good output
capacity,
-
-
--
1
1
I
,
~

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1956 crown imperial1956 new yorker1956 windsor

Table of Contents