Install The Poe Power Supply Slot Filler - Cisco 4451 ISR Hardware Installation Manual

4000 series integrated services routers
Table of Contents

Advertisement

Chapter 6
Install and Upgrade Internal Modules and FRUs
Step 3
Replace PoE converter power supply filler. See
details.
After you remove the PoE converter PSU, you need to either install a replacement power or put the filler.

Install the PoE Power Supply Slot Filler

You cannot keep the slot empty, you need to install the filler. To install a PoE power supply slot filler:
Step 1
Remove the bezel and fan tray from the router.
Step 2
Insert the filler tab into the slot on the chassis.
Step 3
Tighten the screws into the securing nuts on the chassis. See
Figure 6-42
1
3
5
OL-32185-02
Install the PoE Converter Power Supply
2
1
Latch to secure module (shown open).
PoE converter module installed in PoE slot 1. 4
Latch to secure PoE converter module (shown
closed).
Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
PoE Converter Power Supply Unit
"Remove PoE Power Supply Slot Filler"
Figure 6-41
for details.
3
5
4
2
PoE converter module being installed in PoE
slot 0.
Screws to secure PoE module to router
chassis.
section for