6.
Follow the onscreen instructions. Touch the screen at the five specified points to
calibrate.

Enabling the Embedded UI on NI Linux Real-Time

The NI TSM-101x monitor requires a USB connection for touch-screen modality on NI Linux
Real-Time targets.
Note
NI Linux Real-Time does not support RS-232 touch screen modality.
Use a USB cable to connect the monitor to the target and complete the following steps to
enable touch screen modality.
Installing the Touch Panel Driver on NI Linux Real-Time
1.
Install the recommended software set on the target.
a)
In MAX, expand Remote Systems in the configuration tree, then expand the RT
target by clicking the arrow beside it.
b)
Select Software.
c)
Click Add/Remove Software at the top of the Software tab to launch the LabVIEW
Real-Time Software Wizard.
d)
Select a recommended software set to install. Click Next. MAX displays installation
progress, and restarts the target.
2.
Select the Enable Embedded UI checkbox in MAX.
a)
Expand Remote Systems in the configuration tree, then select the RT target.
b)
Place a check in the Enable Embedded UI checkbox.
c)
Click Save, then select Yes when prompted to restart the target.
Calibrating the Touch Screen on NI Linux Real-Time
The touch screen may be out of calibration on first use. Visit
Code
CalibrateTouchScreenLinuxRT
NI TSM-101x touch screen on an RT target.

Connecting the NI TSM-101x to Power

Caution
NI TSM-101x.

Wiring the Terminal Block

Connect the leads of the 9 to 36 V DC power supply into the terminal block.
Caution
must not exceed 3 m (10 ft).
Use wire that meets the requirements in the device specifications. Attach the power and
ground wires to the correct sockets of the connector as shown in the following figure.
Connect earth ground to the grounding electrode system of your facility using a method
appropriate for the application.
6 | ni.com | NI TSM-101x User Manual
You must use a UL Listed ITE power supply marked LPS with the
To ensure the specified EMC performance, the length of all power wiring
ni.com/info