PROGRAMMING UP TRAVEL LIMIT
Programming UP Limit:
1. Press and hold the UP arrow button.
Long LED will light BLUE.
2. Release UP arrow button.
Round LED will ash BLUE.
3. Press and hold the UP arrow button until door
is fully open.
Use the DOWN arrow button if door opens
too far. Use both UP and DOWN buttons to
adjust open travel as necessary.
SECTIONAL DOOR UP LIMIT:
Door should fully open so that door seal is even
with door header. Do not adjust so much that
the door will bend, buckle or stretch door spring
cables backward. Stop carriage short of the opener
powerhead.
ONE-PIECE DOOR UP LIMIT:
Door should fully open so that the door arms will be
in line and push forward and up on the door.
Door damage can result If up limit is set too far
back and door arms are angled downward pushing
against the natural travel direction. Fig. A
4. Press and release the SET/PRGM button
Both LEDs will ash BLUE then go out.
The UP limit is now programmed.
One-Piece Door Limit Setting
Fig. A
Proper UP limit setting
UP limit set too high
1-2. Enter Programming Mode
3. Adjust Door Position
Correct
4. Lock Programming
Angle
Incorrect
Angle
PRGM
SET
Steady Blue
PRGM
SET
Flashing Blue
PRGM
SET
PRGM
SET
Flashing Blue
PRGM
SET
HOLD
UNTIL
LED
LIGHTS
RELEASE
PRESS
&
RELEASE
9