STEP 2

Health

68
You must save your current configuration before changing the TCAM Allocation
Settings.
A summary of the TCAM entries actually in use and available is
NOTE
displayed at the bottom of this page. For an explanation of the fields, see
<300-500>Viewing TCAM
Save the new settings by clicking Apply. This checks the feasibility of the TCAM
allocation. If it is incorrect, an error message is displayed. If it is correct, the
allocation is saved to the Running Configuration file and a reboot is performed.
The Health page monitors the fan status on all devices with fans. Depending on the
model, there are one or more fans on a device. Some models have no fans at all.
On devices on which a temperature sensor is assembled, for protecting the device
hardware in case it overheats, the following actions are performed by the device if
it overheats and during the cool down period after overheating:
Event
At least one temperature
sensor exceeds the
Warning threshold
At least one temperature
sensor exceeds the Critical
threshold
Cisco Small Business 200, 300 and 500 Series Managed Switch Administration Guide (Internal Version)
Utilization.
Action
The following are generated:
SYSLOG message
SNMP trap
The following are generated:
SYSLOG message
SNMP trap
The following actions are performed:
System LED is set to solid amber (if hardware
supports this).
Disable Ports — When the Critical
temperature has been exceeded for two
minutes, all ports will be shut down.
(On devices that support PoE) Disable the
PoE circuitry so that less power is consumed
and less heat is emitted.
Administration
Health