Advertisement

Technical data of the D4x5-2

5.4 Power supply

5.3

Dimensions and weights

Dimensions and weights
Table 5-4
Parameter
Dimensions W x H x D [mm]
● Without fastening using spacers,
● With fastening using spacers,
Weight [g]
- Without packaging
- With packaging
Note
The spacers can be removed for D425-2 and D435-2.
D425-2 and D435-2 do not have any cooling fins.
The presence of cooling fins for D445-2 DP/PN and D455-2 DP/PN means the spacers can
be removed only for the "external cooling" installation type. In this installation method, the
cooling fins are inserted through a cutout in the rear cabinet panel.
For further details, see the
Manual.
5.4
Power supply
External 24 V power supply
The control unit is supplied by an external 24 V power supply (e.g. SITOP).
The tolerance range for the input voltage of the SIMOTION D4x5‑2 is between 20.4 and
28.8 VDC.
80
Dimensions and weight of a SIMOTION D4x5‑2
without fan/battery module
without fan/battery module
D425-2 DP
D425-2 DP/PN
D435-2 DP
D435-2 DP/PN
50 x 380 x 230
50 x 380 x 270
Approx. 3.6 kg
Approx. 4.2 kg
SIMOTION D4x5-2 Commissioning and Hardware Installation
D445-2 DP/PN
D455‑2 DP/PN
50 x 380 x 230
50 x 380 x 270
Approx. 4.4 kg
Approx. 5.0 kg