Safety Information; Interface Description - Siemens SIMOTION D425-2 Manual

Hide thumbs Also See for SIMOTION D425-2:
Table of Contents

Advertisement

Supplementary system components
7.4 CBE30-2 Ethernet communication board
7.4.3

Safety information

NOTICE
CBE30‑2 damage caused by electric fields or electrostatic discharge
Option boards are ESD-sensitive components.
De-energize the SIMOTION D4x5‑2 device before inserting or removing the option board.
The SIMOTION D4x5‑2 is in a de-energized state when all the LEDs are off.
Observe the ESD guidelines (see Section ESD guidelines (Page 141)).
7.4.4

Interface description

Characteristics
The X1400 interface has full-duplex 10/100 Mbit Ethernet ports. The module has an integrated
4-port switch.
Interface characteristics
Table 7-13
Characteristic
Connector type
Cable type
Maximum cable length
Dust protection filler plugs for sealing unused
PROFINET ports
Interface assignment
Table 7-14
X1400 interface
Representati
Pin
on
1
2
3
4
5
112
X1400 features
Name
TXP
TXN
RXP
--
--
Type
RJ45 socket
Industrial Ethernet cable
100 m
5 filler plugs contained in the D4x5‑2 scope of
delivery
Filler plugs (50 pcs) order number:
6SL3066‑4CA00-0AA0
Signal type
Output
Output
Input
Description
Ethernet transmit differential signal
Ethernet transmit differential signal
Ethernet receive differential signal
4 together with 5 via 75 ohm at the 1 nF
capacitor to the shield ground
4 together with 5 via 75 ohm at the 1 nF
capacitor to the shield ground
SIMOTION D4x5-2