Led Displays - Siemens SIMOTION D425-2 Manual

Hide thumbs Also See for SIMOTION D425-2:
Table of Contents

Advertisement

Representati
Pin
on
6
7
8
Screened
backshell
Position of the ports
The interfaces are located on the front side of the CBE30‑2.
Figure 7-10
7.4.5

LED displays

Position of the LEDs
The X1400 interface with the four ports has integrated LEDs for displaying the link and the
activity for each port. The front panel of the board is also fitted with two LEDs (Fault and Sync),
which indicate the bus status.
Table 7-15
LED
link
Activity
Sync
Fault
SIMOTION D4x5-2
Manual, 04/2014
Name
RXN
--
--
M_EXT
CBE30‑2 interface
Meaning of the LED displays
Meaning
... indicates whether a different device is connected to port x and a physical
connection exists
... indicates whether data is being received or sent at port x
... indicates the synchronization status of the PROFINET IO interface
... indicates a fault state of the PROFINET IO interface
7.4 CBE30-2 Ethernet communication board
Signal type
Input
Supplementary system components
Description
Ethernet receive differential signal
7 together with 8 via 75•ohm at the 1•nF
capacitor to the shield ground
7 together with 8 via 75 ohm at the 1-nF
capacitor to the shield ground
Screen, permanently connected
113