Available languages

Installation
Figure 4
Holes for
securing to
framing
for the CDFI1000-PRO and 40in
(258 cm
) for the CDFI500-PRO,
2
is required for optimum mist
production. The air intake must
allow for air to reach the underside
of the Opti-myst Cassette
(Figure 2 & 3). If installing into
the Opti-myst Pro Box Heater
(optional), no additional air intake
is required. The Opti-myst Pro Box
Heater is designed with air intakes
included.
For optimal performance, a
clearance of 18 in (457 mm)
between the installation surface
and any surface above should be
maintained. A minimum clearance
of 16 in (405 mm) must be
maintained.
2.
In the back left corner of
the unit, locate and remove
the electrical cover plate, by
removing the two securing
screws.
10
Electrical Cover Plate
Cable Plate
Cord Outlet
for Tethered
Controller
3.
Install a ⅜ in (10 mm) or ½ in
(13 mm) cable connector, not
included, suitable for mounting
in a ⅞ in (22 mm) hole, to the
cable plate and feed the supply
cable through the connector.
The cable plate can be
removed by removing the two
securing screws on either side,
to allow for easier access.
CAUTION: Use two conductor,
non-metallic sheath cable with
ground wire (3 wires total) for the
2
incoming power supply on the
cassette. Use appropriate wire to
meet local and national electrical
codes for rated power.
!
NOTE: When installing multiple
units in the same vicinity they will
need to be wired in parallel.
!
NOTE: The Opti-myst
is designed to allow for installation
of a wall switch to control the
incoming power to the unit.
4.
Connect the black wire (live)
from the unit to the live from
the power supply.
5.
Connect the white wire
(neutral) from the unit to the
neutral wire from the power
supply.
6.
Connect the green wire
(ground) from the unit to the
ground wire from the power
supply.
cassette
®