EIB / KNX
3.2.3.1 Parameter window
"A – Output"
Commissioning
Fig. 16: Parameter window "Channel A – Output"
Send output value
Options:
on request
after a change
cyclically
after a change and cyclically
This parameter is used to define how the Output value should be sent.
Option On request = Send output value on request
When this option is selected, the "Output value – Channel A" communi-
cation object appears. As soon as a "1" is received at this communication
object, the current output value is sent once to the "Output value –
Channel A" communication object.
Option After a change = Send output value after a change
Option Cyclically = Send output value cyclically
Option After a change and cyclically = Send output value after a change
and cyclically
In the case of the after a change, cyclically and after a change and cyclically
options, further parameters appear – see next page.
Output value is sent, every
Options:
5 s/10 s/30 s/1 min/5 min/10 min/30 min/1 h/6 h/12 h/24 h
This additional parameter is used to set the interval for cyclical sending.